6-2
DVP-NC60P
(6)
Error code list
01: Communication error (No reply from syscon)
02: Syscon hung up
03: Power OFF request when syscon hung up
19: Thermal shutdown
24: MoveSledHome error
25: Mecha move error (5 Changer)
26: Mecha move stack error
30: DC Motor adjustment error
31: DPD offset adjustment error
32: TE Balance adjustment error
33. TE Sensor adjustment error
34. TE loop gain adjustment error
35. FE loop gain adjustment error
36. Bad jitter after adjustment
40. Focus NG
42. Focus Layer Jump NG
52. Open kick spindle error
51: Spindle stop error
60: Focus on error
61: Seek fail error
62: read Qdata/ID error
70: Lead In Data Read Fail
71: TOC read time out (CD)
80: Can’t Buffering
81: Unknown media type
(7)
Error code parameters
Example of Error code
1. 01 05 04 04
00 92 46 00
00 00 00 00
00 00 23 45
This is the detailed contents od error information
(8)
Laser hours at error happend.
Example of Error code
1. 01 05 04 04
00 92 46 00
00 00 00 00
00 00 23 45
This is Laser hours when an error happaned.
(9)
How to Clearing laser hours
Press
[DISPLAY]
,
[CLEAR]
keys in this order.
Both CD and DVD data are cleared.
Emg. History Check
Laser Hours
CD
0 h
0min
DVD
0 h
0min
1. 01 05 04 04
00 92 46 00
00 00 00 00
00 00 23 45
2. 02 02 01 01
00 A9 4B 00
00 00 00 00
00 00 23 45
[Next]
Next Page
[Prev]
Prev Page
-
Return to Top Menu
(10)
How to Clearing Emergency code
Press
[TOPMENU]
,
[CLEAR]
keys in this order.
All emergency code are cleared.
Emg. History Check
Laser Hours
CD
999h
59min
DVD
999h
59min
1. 00 00 00 00
00 00 00 00
00 00 00 00
00 00 00 00
2. 00 00 00 00
00 00 00 00
00 00 00 00
00 00 00 00
[Next]
Next Page
[Prev]
Prev Page
(11)
Press
-
key, return to TOP MENU.
6-3.
INITIALIZING SETUP DATA
How to initializing setup data.
(1)
In stanby mode, press
[TOP MENU]
,
[CLEAR]
,
[POWER]
to enter Remocon Diagnosis Mode.
(2)
Select “3. Emergency History”.
Emg. History Check
Laser Hours
CD
999h
59min
DVD
999h
59min
1. 01 05 04 04
00 92 46 00
00 00 00 00
00 00 23 45
2. 02 02 01 01
00 A9 4B 00
00 00 00 00
00 00 23 45
[Next]
Next Page
[Prev]
Prev Page
(3)
Initializing setup data
Press
[MENU]
,
[CLEAR]
keys in this order.
The data have been initialized when “Initialize setup
data...” mesage is displayed.
Emg. History Check
Laser Hours
CD
999h
59min
DVD
999h
59min
Initialize setup data ...
[Next]
Next Page
[Prev]
Prev Page
Summary of Contents for DVP-NC60P - Cd/dvd Player
Page 32: ...2 10E DVP NC60P MEMO ...
Page 73: ...7 4E DVP NC60P MEMO ...
Page 76: ......
Page 78: ......