6-7
DVP-NS28/NS38/NS39/NS47P/NS57P/NS64P/NS67P
2-3-5. FLD Anode Test Display and SHUTTLE Click Operation Test
2-3-5-1. Transition Keys in Self Check Mode
•
t
key on the remote commander
• SHUTTLE on the remote commander during Anode Test display (This unit does not provide JOG/SHUTTLE, and therefore use another DVD
remote commander having the JOG/SHUTTLE)
2-3-5-2. Operation and Display
The Self Check Mode transits to this mode when
t
key is entered. This tests whether each segment turns on individually. Only the first segment
of each grid of FLD turns on, and each time the SHUTTLE is entered, the segment of each grid switched in order. When SHUTTLE input is
clockwise or remote number 6, the segment switches in 1 - 2 -3 direction, or counterclockwise or remote number 4 it switches in 3 - 2- 1 direction.
• Display at the start of Anode Test
r
(Input in CW direction)
2-3-6. FLD Grid Test Display and SHUTTLE Click Operation Test
2-3-6-1. Transition Keys in Self Check Mode
•
R
key on the remote commander
• SHUTTLE on the remote commander during Grid Test display
(This unit does not provide JOG/SHUTTLE, and therefore use another DVD remote commander having the JOG/SHUTTLE)
2-3-6-2. Operation and Display
The Self Check Mode transits to this mode when
R
key is entered. This tests whether each grid turns on individually. The first grid only of FLD
turns on and other grid turn off. Each time the SHUTTLE is entered, the grid is switched in order. When SHUTTLE input is clockwise or remote
number 6 repeatedly, the grid switched in 1 - 2 - 3 direction, or counterclockwise or remote number 4 repeatedly it switches in 3 - 2 - 1 direction.
• Display at the start of Grid Test