7-1
DVP-NS28/NS38/NS39/NS47P/NS57P/NS64P/NS67P
This section describes procedures and instructions necessary for
adjusting electrical circuits in this unit.
Instruments required:
(1) Color monitor TV
(2) Oscilloscope 1 or 2 phenomena, band width over 100 MHz, with
delay mode
(3) Frequency counter (over 8 digits)
(4) Digital multimeter
(5) Standard commander (RMT-D175A/D175P)
(6) DVD reference disc
HLX-501 (J-6090-071-A) (dual layer) (NTSC)
HLX-503 (J-6090-069-A) (single layer) (NTSC)
HLX-504 (J-6090-088-A) (single layer) (NTSC)
HLX-505 (J-6090-089-A) (dual layer) (NTSC)
7-1. POWER SUPPLY OUTPUT VOLTAGE
CHECK
Mode
Except standby
Instrument
Digital multimeter
EVER +5 V Check
Test point
CN201 pin
4
Specification
5.0 ± 0.3 Vdc
SW +3.3 V Check
Test point
CN201 pin
5
Specification
3.35 ± 0.2 Vdc
SW+5 V Check
Test point
CN201 pin
6
Specification
5.0 Vdc
SW +8 V Check
Test point
CN201 pin
1
Specification
8.0 ± 0.5 Vdc
EVER +11 V Check
Test point
CN201 pin
3
Specification
11.0 Vdc
EVER –10 V Check
Test point
CN201 pin
q;
Specification
–10.0 Vdc
Checking method:
(1) Confirm that each voltage satisfies the specification.
Caution!
Please do not touch any electrical parts at primary circuit to avoid
electrical shock.
+0.5
–1.0
+1.0
–0.5
+0.2
–0.3
SECTION 7
ELECTRICAL ADJUSTMENT
www. xiaoyu163. com
QQ 376315150
9
9
2
8
9
4
2
9
8
TEL 13942296513
9
9
2
8
9
4
2
9
8
0
5
1
5
1
3
6
7
3
Q
Q
TEL 13942296513 QQ 376315150 892498299
TEL 13942296513 QQ 376315150 892498299