6-11
6-8.
VERSION INFORMATION
## Version Information ##
IF con.
Ver : x. xxx (xxxx)
Group 00
SYScon.
Ver : x. xxx (xxxx)
Model xx
Region 0x
Servo DSP. Ver : 1. xxxx
OPT Type : x LASER
Exit: RETURN
_
The ROM version, region code, OPT type, etc. are displayed if
[5]
is selected in the Test Mode Menu.
The parenthesized hexadecimal number in the version number field
indicates the checksum value of the ROM.
Note : After down loading ROM data, sometimes it happens that
checksum is not the same as that of ROM data which has
been down loaded. In such a case, go back to the menu
and select “0. Syscon Diagnosis”, then select “1. All” in
“2. Version”. If the result of this operation does not give
an agreement, it must be either Down Load error or ROM
error.
6-9.
VIDEO LEVEL ADJUSTMENT
On the Test Mode Menu screen, selecting
[6]
displays color bars
for video level adjustment. During display of color bars, OSD dis-
appears but the menu screen will be restored if pressing any key.
Measurement point
: LINE OUT VIDEO
(75
Ω
terminating resistance)
Measuring instrument : Oscilloscope
Adjustment device
: RV501 on MB-101 board
Specified value
: 1.00
+ 0.04
Vp-p
– 0.02
1.00
+ 0.04
Vp-p
– 0.02
6-10. IF CON SELF DIAGNOSTIC FUNCTION
1. FL-125 BOARD (IF CON) TEST MODE
The front board test mode is the IF CON self diagnostic mode.
The IF CON can diagnose the functions of the front panel boards
that the IF CON controls. Normally, the IF CON makes a serial
communication with the SYSTEM CONTROL and operates fol-
lowing the commands from the SYSTEM CONTROL, but in the
Test mode, the IF CON operates independently from the SYS-
TEM CONTROL.
In the Test mode, the following functions can be checked.
1. Button function
2. Remote commander receiving function
3. SYSTEM CONTROL-IF CON serial communication
4. Click shuttle function
5. Fluorescent display tube lighting check
Grid check
Anode check
6. LED control function
In the Test mode, the set operates same as usual, except voltage
monitoring, communication monitoring, display of fluorescent
display tube, and LED control.
1. The routine that mo3.3 V (P-CONT) of MB-101 board
is not provided.
2. The monitoring timer for serial communication with the SYS-
TEM CONTROL is not provided. The set is not placed in the
Standby mode, even if the communication with SYSTEM
CONTROL is normal.
3. Display of fluorescent display tube (normally, display is made
following the commands from SYSTEM CONTROL)
4. LED control (normally, control is made following the com-
mands from SYSTEM CONTROL)
2. OPERATION OF SELF CHECK MODE
The Self Check mode is the function to conduct the basic test to
the FL display and DVD panel section.
2-1. Self Check Mode Transition Processing
At the AC Power ON after IF CON (IC703) was reset, the input to
10pin (SELF CHECK) is judged and if “Low” is entered, the main
unit transits to the Self Check mode. In this port input judgment,
the result of 3-time attempts must be same (assuming that the MB-
101 board is not connected). While pressing the
[STOP]
key on the
main unit with the IF CON in STANDBY mode, enter
[RETURN]
→
[DISPLAY]
(or
[SET UP]
) on the remote commander, and the unit
transits to the Self Check Mode. The Self Check mode terminates
when the IF CON transits to the STANDBY mode.