xx
Note:
Check these Serial Numbers also
. If your serial number falls within the following range, You must
change
the following resistors
on the main board, as well as the SYSCOM ROM. After resistors are changed, perform the Drive Auto Adjustment. If unit is not in
range,confirm version of SYSCON, replace if necessary, and do
the Drive Adjustment.
DVPS330
100001 to 135300 and 800001 to 836000
DVPS530D
800001 to 840000
DVPS550D
800001 to 843000
DVPC650D
Not Applicable
RESISTORS Remove and Replace with new part
R305 (NEW PART )
Part Number 1-216-837-11
Change from 10K
Ω
to 22K
Ω
R307 (NEW PART
Part Number 1-216-839-11
Change from 15K
Ω
to 33K
Ω
Summary of Contents for DVP-S300
Page 4: ...1 NOTES ...
Page 13: ...10 NOTES ...
Page 19: ...16 NOTES ...
Page 25: ...22 NOTES ...
Page 29: ...26 NOTES ...
Page 35: ...32 2ND GENERATION OPTICAL ASSEMBLY SYMPTOM 3 1 3 01 19DVD03 ...
Page 39: ...36 NOTES ...
Page 61: ...58 Flex Cable DVP C650 ...
Page 71: ...68 NOTES ...
Page 76: ...APPENDIX ...