15-4
Chapter 15
DIAGNOSIS Menu Operations
Displaying Error Messages
You can use the ERROR MESSAGE menu to display error messages for the
switcher and DME connected to the control panel.
To display error messages, use the following procedure.
1
In the DIAGNOSIS menu, select item 5 (ERROR), then press F3
(ERROR MESSAGE).
The ERROR MESSAGE menu appears.
F1
F2
F3
F4
F5
F6
F7
F8
F9
F10
CH2
CH1
PANEL
[POPUP]
CLEAR
CH4
SWER
PROC
CH3
DME PROC
Function key indications in the ERROR MESSAGE menu
If any function key is flashing, it indicates an error has occurred on the
corresponding equipment.
2
Press the flashing function key to display the error message.
To clear the error message if displayed even after correction of
the error
Even after the error is corrected, the error message may remain displayed.
To clear the error message in such a case, press F10 (CLEAR).
If the error is no longer present, the error message will disappear.
To temporarily clear an error message and turn off the alarm
buzzer
When an error is detected causing the corresponding error message to
appear and the alarm buzzer to sound, you can temporarily clear the error
message and turn off the alarm buzzer by holding down the SHIFT button
and pressing F10 (POPUP) in the ERROR MESSAGE menu.
In this case, resetting the control panel before correcting the error will
cause the same error message to appear and the alarm buzzer to sound
again.
Operations
Summary of Contents for DVS-7250
Page 10: ......
Page 30: ......
Page 66: ......
Page 67: ...Menu Organization 3 2 Basic Menu Operations 3 6 Chapter 3 Basic Menu Operations ...
Page 274: ......
Page 328: ......
Page 364: ......
Page 488: ......
Page 495: ...Appendixes A 3 Enhanced Wipes 21 23 24 26 27 29 49 300 301 302 303 304 POLYGON ...
Page 534: ......
Page 542: ...Sony Corporation B P Company BZS 7061A WW A AE0 600 01 1 1999 ...