5-31
5-2. Servo/DT System Check Mode
b) C051: SG LOOP CHECK
This mode checks the feedback loop of the strain gauge.
(1) Set the “*” mark to “Start auto check” using a search dial (JOG mode).
(2) When the SET button (or switch S300 on the SS board) is pressed after the
“Push SET button” message is displayed, this check is initiated.
(3) Confirm that the check is completed and that the “CHECK COMPLETE”
message is displayed on the monitor screen.
In case of NG; (The screen at right is one example.)
When the “CHECK COMPLETE” message is not displayed on the monitor
screen.
Execute the DT driver check (C050: DT DRIVER CHECK).
If no abnormality is found in this case, check the advance head/strain gauge of
the inner drum or its signal transmission system (slip ring etc.).
(1) DIAL
(2)
[SET]
or
[S300]
During check
Check completed (OK)
Check completed (NG)
DIGITAL DT CHECK
C051:SG LOOP CHECK
*No operation
Start auto check
DIGITAL DT CHECK
C051:SG LOOP CHECK
No operation
*Start auto check
CHECKING......
DIGITAL DT CHECK
C051:SG LOOP CHECK
No operation
*Start auto check
CHECK COMPLETE
DIGITAL DT CHECK
C051:SG LOOP CHECK
No operation
*Start auto check
# CHECK INCOMPLETE #
A/Bch
Summary of Contents for DVW-522
Page 6: ......
Page 40: ......
Page 49: ...2 9 2 4 1 Printed Circuit Board Locations Rear view Front view ...
Page 50: ...2 10 Top view of casssette compartment 2 4 1 Printed Circuit Board Locations Top view ...
Page 64: ......
Page 68: ......
Page 82: ......
Page 134: ......
Page 136: ...7 2 7 2 OVERALL 1 4 OVERALL 1 4 7 2 Overall Signal Processing System OVERALL 1 4 DVW 522 522P ...
Page 137: ...7 3 7 3 OVERALL 2 4 OVERALL 2 4 Signal Processing System OVERALL 2 4 DVW 522 522P ...
Page 140: ......