1-13
EVI-D100/EVI-D100P
1-6. Judge for No Video Picture Output
FCB/EVI CONTROL INTERFACE TOOL and FLEXIBLE HARNESS 20P are required for easily
determining whether the camera block is faulty or not when a video signal is not output from the unit.
Connection
Procedure
1.
Turn the switch S001 to ON.
2.
The video output picture becomes blue.
3.
After 5 seconds, the video output changes from all blue to Full Auto output.
4.
If items 2 and 3 are satisfied, camera block is all right.
CN501
CN010
CN010
CN501
This side is blue line.
DC IN 9 V (J001)
Use an AC adaptor with
the DC output plug of 4.75 mm
in diameter.
Do not use the AC adaptor
that is supplied with the unit.
VIDEO OUT
This side is contact.
DD-161/161P board
Color monitor
S001
Ensure to turn it off
before use.
FCB/EVI CONTROL
INTERFACE TOOL
(J-6432-960-B)
FLEXIBLE
HARNESS (20P)
(J-6433-090-A)
75
Z
termination
AC adaptor