2-20
EVI-D100/EVI-D100P
6-2. Flange Back Adjustment (2)
Perform this adjustment after performing “Flange Back
Adjustment (1)”.
Subject
Subject more than 500 m away
(Subjects with clear contrast such
as buildings, etc.)
Measurement Point
Check operation on TV monitor
Measuring Instrument
Adjustment Page
F
Adjustment Address
3E to 42, 76 to 7B
Adjusting method
1) Set the zoom lens to the TELE end and expose a
subject that is more than 500 m away (subject with
clear contrast such as building, etc.). (Nearby subjects
less than 500 m away should not be in the screen.)
2) Select page: 0, address: 01, and set data: 01.
3) Select page: 2, address: 02, and check that the data is
“00”.
4) Select page: 2, address: 01, set data: 13, and press the
PAUSE button of the adjusting remote commander.
5) Place a ND filter on the lens so that the optimum
image is obtain.
6) Select page: 2, address: 01, set data: 29, and press the
PAUSE button of the adjusting remote commander.
(The adjustment data will be automatically input to
page: F, addresses: 3E to 42, 76 to 7B.)
7) Select page: 2, address: 02, and check that the data is
“01”.
Processing after Completing Adjustments
1) Select page: 0, address: 01, and set data: 00.
2) Turn OFF the main power supply.
3) Perform “Flange Back Check”.
7. Flange Back Check
Subject
Siemens star
(2.0 m from the front of the lens)
(Luminance: approx. 200 lux)
Measurement Point
Check operation on TV monitor
Measuring Instrument
Specified Value
Focused at TELE end and WIDE end.
n
*
: When the auto focus is ON, the lens can be checked if
it is focused or not by observing the data on the page 1
of the adjusting remote commander.
1)
Select page: 0, address: 03, and set data: 0F.
2)
Page 1 shows the state of the focus.
1 : 00 : XX
Odd: Focused
Even: Unfocused
Checking method
1) Place the Siemens star 2.0 m from the front of the lens.
2) To open the IRIS, decrease the luminous intensity to
the Siemens star up to a point before noise appear on
the image.
3) Select page: 2, address: 40, and set data: 02.
4) Select page: 2, address: 41, and set data: 01.
5) Shoot the Siemens star with the zoom TELE end.
6) Turn on the auto focus.
7) Check that the lens is focused (
*
).
8) Select page: 2, address: 21, and set data: 10.
9) Shoot the Siemens star with the zoom WIDE end.
10) Observe the TV monitor and check that the lens is
focused.
Processing after Completing Adjustments
1) Select page: 2, address: 21, and set data: 00.
2) Select page: 0, address: 03, and set data: 00.
3) Select page: 2, address: 40, and set data: 00.
4) Select page: 2, address: 41, and set data: 00.