(4) Transmission at 81010609FF (Adjustment starts)
Command of 9041FF is returned to Response Window. Afterward, DC level and amplitude of a MR
sensor, and positions of a reset sensor and mechanism termination point are measured.
(5) The measuring result and error code are returned to Response Window after completing
measurements. (Refer to Table. 1) When error code 00h appears, measurements are completed
normally. Then data is stored in EEPROM and restart a camera automatically.
n
When error code appears except 00h, it may cause by failure of adjustment operation or a camera
operates abnormally. (Refer to Table. 2) If required, perform repair and readjustment. When turn on
the power once, repeat above steps (1) to (5).
Command
81 01 06 09 FF
Reply
90 41 FF
Ack
90 50 0p 0q 0r 0s FF
Data 1
Pan MR DC level pq=FG0, rs=FG1
90 50 0p 0q 0r 0s FF
Data 2
Tilt MR DC level pq=FG0, rs=FG1
90 50 0p 0q 0r 0s FF
Data 3
Pan MR amplitude pq=FG0, rs=FG1
90 50 0p 0q 0r 0s FF
Data 4
Tilt MR amplitude pq=FG0, rs=FG1
90 50 0p 0q 0r 0s FF
Data 5
pqrs=Pan reset sensor (left) position
90 50 0p 0q 0r 0s FF
Data 6
pqrs=Pan reset sensor (right) position
90 50 0p 0q 0r 0s FF
Data 7
pqrs=Pan mechanism termination point distance
90 50 0p 0q 0r 0s FF
Data 8
pqrs=Tilt reset sensor (bottom) position
90 50 0p 0q 0r 0s FF
Data 9
pqrs=Tilt reset sensor (top) position
90 50 0p 0q 0r 0s FF
Data 10
pqrs=Tilt mechanism termination point distance
90 51 xx FF
Completion
xx=Error code (Refer to Table 2)
Table 1 Pan and Tilt Adjustment