Command List
FCB-EH6500(GB) A-EEP-100-11(1)
Responses for commands and inquiries
ACKNOWLEDGE message
Returned by the FCB camera when it receives a
command. No ACKNOWLEDGE message is
returned for inquiries.
Completion message
Returned by the FCB camera when execution of
commands or inquiries is completed. In the case of
inquiry commands, it will contain reply data for the
inquiry after the 3rd byte of the packet. If the
ACKNOWLEDGE message is omitted, the socket
number will contain 0.
Reply Packet
Note
ACKNOWLEDGE
X0 4Y FF
Y = socket number
Completion (commands)
X0 5Y FF
Y = socket number
Completion (Inquiries)
X0 5Y ... FF
Y = socket number
X = 9 to F: FCB camera a 8
Error message
When a command could not be executed or failed,
an error message is returned instead of the
ACKNOWLEDGE message. After an
ACKNOWLEDGE message, an error message may
be returned if the process of some command (zoom,
etc.) has not been completed.
When a inquiry command could not be executed or
failed, an error message is returned instead of the
completion message.
Error Packet
Description
X0 6Y 01 FF
Message length error (>14 bytes)
X0 6Y 02 FF
Syntax Error
X0 6Y 03 FF
Command buffer full
X0 6Y 04 FF
Command cancelled
X0 6Y 05 FF
No socket (to be cancelled)
X0 6Y 41 FF
Command not executable
X = 9 to F: FCB camera a 8, Y = socket number
Socket number
When command messages are sent to the FCB camera,
send the next command message after waiting for the
completion message or error message to return.
However to deal with advanced uses, the FCB camera
has two buffers (memories) for commands, so that up
to two commands including the commands currently
being executed can be received. When the FCB camera
receives commands, it notifies the sender which
command buffer was used using the socket number of
the ACKNOWLEDGE message. As the completion
message or error message also has a socket number, it
indicates which command has ended. Even when two
command buffers are being used at any one time, an
FCB camera management command and some inquiry
messages can be executed.
The ACKNOWLEDGE message is not returned for
these commands and inquiries, and only the
completion message of socket number 0 is returned.
Command execution cancel
To cancel a command which has already been sent,
send the Cancel command as the next command. To
cancel one of any two commands which have been
sent, use the cancel message.
Cancel Packet
Note
Cancel
8X 2Y FF
Y = socket number
X = 1 to 7: FCB camera address, Y = socket number
An error message will be returned for this command,
but this is not a fault. It indicates that the command has
been canceled.