1
Command List
FCB-EH6500(GB) A-EEP-100-11(1)
Register Setting
The register settings are enabled when the power is
turned off and then back on again. After turning the
power back on again, verify that the mode settings have
been changed.
Register No.
Value
VISCA
Baud Rate
00
00
(Default value)
9600 bps
01
19200 bps
02
38400 bps
03
115200 bps
Monitoring
Mode
72
01
(Default value)
1080i/59.94
02
Reserved
03
NTSC Analog Output
(Stop Digital Output)
04
1080i/50
05
PAL Analog Output
(Stop Digital Output)
06
1080p/29.97
07
Reserved
08
1080p/25
09
720p/59.94
0A
Reserved
0B
Reserved
0C
720p/50
0D
Reserved
0E
720p/29.97
0F
Reserved
10
Reserved
11
720p/25
12
Reserved
13
1080p/59.94
14
1080p/50
Output
Enabling
73
01
Analog Output
enabled
02
Digital Output
enabled
03
(Default value)
Both Analog/Digital
Output enabled
LVDS Mode
74
00
(Default value)
Single output
01
Dual output
Zoom Limit
50
00-FF
(Default value: 00)
Wide Limit
(0: Disabled)
51
00-FF
(Default value: 00)
Tele Limit
(0: Disabled)
D-Zoom Max
52
00-EB
(Default value: EB)
Max. digital
zoom ratio =
256 ÷ (256-Value)
StableZoom
53
00
(Default value: 00)
OFF
01
ON
Temperature Reading Conversion Value
(Reference Value)
Reading Value
pq (hex)
Temperature
Conversion
Value (ºC)
FB
−8 to −2
00
−3 to +3
0A
7 to 13
14
17 to 23
1E
27 to 33
28
37 to 43
32
47 to 53
3C
57 to 63