background image

29

FCB-IX47/IX47P

FCB-IX470/IX470P

Response for command and inquiry

ACK message

: Returned by the FCB camera when it receives the command. No ACK message is returned for

inquiries.

Completion message : Returned by the FCB camera when execution of commands and inquiries is completed. In the case

of inquiry commands, it will contain reply data for the inquiry after the 3rd byte of the packet. If the

ACK message is omitted, the socket number will contain a 0.

Reply Packet

Note

Ack

X0 4Y FF

Y = socket number

Completion (commands)

X0 5Y FF

Y = socket number

Completion (Inquiries)

X0 5Y ... FF

Y = socket number

X = 9 to F: FCB camera a 8

Error message : When a command or inquiry command could not be executed or failed to be executed, the error message

is returned as instead of the completion message.

Error Packet

Description

X0 6Y 01 FF

Message length error (>14 bytes)

X0 6Y 02 FF

Syntax Error

X0 6Y 03 FF

Command buffer full

X0 6Y 04 FF

Command cancelled

X0 6Y 05 FF

No socket (to be cancelled)

X0 6Y 41 FF

Command not excutable

X = 9 to F: FCB camera a 8, Y = socket number

Socket number

When command messages are sent to the FCB camera, it is normal to send the next command message after waiting for the

completion message or error message to return. However to deal with advanced uses, the FCB camera has two buffers

(memories) for commands, so that up to two commands including the commands being executed can be received. When the

FCB camera receives commands, it notifies which command buffer was used using the socket number of the ACK message.

As the completion message or error message also has a socket number, it indicates which command has ended. Even when two

command buffers are used, the command for FCB camera management and some inquiry messages can be executed.

The ACK message is not returned for these commands and inquiries, and only the completion message of socket number 0 is

returned.

VISCA™/RS-232C

Summary of Contents for FCB-IX47

Page 1: ...Instruction Manual Ver 1 01 English COLOR CAMERA MODULE FCB IX47 IX47P FCB IX470 IX470P ...

Page 2: ...CATIONS 1 DIMENSIONS 2 PIN ASSIGNMENT 3 FUNCTIONS 4 CONTROL METHODS 13 INSTALLATION 16 ECLIPSE 17 HANDLING PRECAUTIONS 18 VIBRATIONAL SPECIFICATIONS 19 INITIAL VALUE AND BACKUP 20 MODE CONDITIONS 21 COMMAND LIST 23 Table of Contents 24 VISCA RS 232C 25 COMMAND LIST 34 ...

Page 3: ...al zoom Angle of view H Min working distance Sync system Min sensitivity S N ratio Back light compensation Electronic shutter White balance Gain Aperture Preset Battery back up Video output Storage temp humidity Operating temp humidity Power Weight Dimensions W H D mm 1 4 Super HAD CCDTM 768 H 494 V 752 H 582 V more than 470 TVL more than 460 TVL 18 zoom f 4 1 to 73 8 mm F1 4 to F3 0 4 72 with opt...

Page 4: ...2 FCB IX47 IX47P FCB IX470 IX470P DIMENSIONS Unit mm FCB IX47 IX47P FCB IX470 IX470P Unit mm ...

Page 5: ... AD6 AF ON LED DIGITAL ZOOM POS OPTICAL ZOOM POS CN805 External control Supplied Accessories There are five cables packed in the shipping unit carton Type of connectors JST CN501 Power Camera side S2B ZR SM3A TF Cable side housing ZHR 2 CN705 Ext battery Camera side S3B ZR SM3A TF Cable side housing ZHR 3 CN301 Video Camera side S6B ZR SM3A TF Cable side housing ZHR 6 CN802 RS 232C Camera side S10...

Page 6: ...ions refer to SW JIG and by VISCA RS 232C Zoom The FCB IX47 P and FCB IX470 P use an 18 zoom lens as well as a 4 digital zoom Optical 18 f 4 1 to 73 8 mm F 1 4 to F 3 0 The horizontal angle of view is approximately 48 wide end to 2 7 tele end The digital zoom is automatically switched ON at the tele end of 18 optical zoom range with a progressive effect from 1 to 4 giving a total maximum 72 zoom r...

Page 7: ...e HIGH AF High reaction speed of AF Use this mode when shooting fast moving objects Recommended as optimum mode for normal NON CONTINUOUS use LOW AF Better focus stability In low luminance conditions AF stops operation even when brightness changes enabling stable images White Balance Auto Auto Tracing White Balance with limitations on R and B gain 3200 to 6000 K to avoid fixing single color scenes...

Page 8: ...ble Iris and Shutter Flicker can be eliminated by setting shutter to 1 100s for NTSC models used in countries with 50 Hz power supply frequency 1 120s for PAL models used in countries with 60 Hz power supply frequency AE Shutter priority The shutter can be set freely by the user to a total of 20 steps 16 high speeds and 4 low speeds When the slow shutter is set the speed can be 1 30s 1 25s 1 15s 1...

Page 9: ...Setting value AE Gain priority The gain can be set freely by the user to 8 steps between 3 dB and 18 dB The shutter speed is fixed and the iris is set automatically according to the brightness of the subject 07 06 05 04 03 02 01 00 18 dB 15 dB 12 dB 9 dB 6 dB 3 dB 0 dB 3 dB Data Setting value AE Manual The shutter speed 20 steps iris 18 steps and gain 8 steps can be set freely by the user 08 07 06...

Page 10: ...at the maintained shutter speed both iris and gain are automatic AE Shutter Auto The iris and gain are set freely by the user and the shutter changes automatically according to the brightness of the subject Slow shutter is disabled AE Iris Auto The gain and shutter are set freely by the user and the iris changes automatically according to the brightness of the subject AE Gain Auto The iris and shu...

Page 11: ...6 7 Data Step Setting value 1 5 dB 3 dB 4 5 dB 6 dB 7 5 dB 9 dB 10 5 dB Aperture Control Aperture control is a function which adjusts the enhancement of the edges of objects in the picture There are 16 steps of adjustment starting from no enhancement When shooting small characters this control may help making them sharper Back Light Compensation When the background of the subject is too bright or ...

Page 12: ...ile memory inside data will be saved regardless of whether it has been backed up Picture Effect It consists of the following functions Pastel Pastel Image Neg Art Negative Positive Reversal Sepia Sepia Image Black White Monochrome Image Solarize Enhanced Contrast Mosaic Mosaic Image Slim Vertical Stretch Stretch Horizontal Stretch 00 01 B 02 C 03 D 04 E 05 F 06 G 07 H A 08 09 J 0a K 0b L 0c M 0d N...

Page 13: ...h nm Relative Response 0 6 0 4 0 2 0 0 500 Cy G Mg Ye 550 600 650 700 CCD Visible Spectral Response IR LED Spectral Response The supplied IR LED has a limited energy range allowing a working distance of approximately 2 to 3 meters NOTE In the 0 lx shot mode the iris is fixed at F1 4 and high speed shutter control cannot be performed Only the gain and low speed shutter can be controlled However iri...

Page 14: ...ns when the power is turned OFF The backup switch can be switched as follows INT side Backs up for about 6 months when the internal battery is fully recharged Full recharge by letting about 24 hours in power ON state OFF side No back up Set to this position at shipment This setting is set when the power is turned ON the next time EXT side Backs up by the external power supply input to the CN705 co...

Page 15: ...is in an auto focus mode Supply 6 to 12 Vdc to CN501 The composite and Y C signals will be output from CN301 The SW memory backup is set to OFF at the shipment When set to INT the zoom and focus states can be backed up The battery backs up the data for six months when fully recharged Most of the camera functions can be controlled by the SW JIG reference circuit Connect the SW JIG by the 12 pin fla...

Page 16: ...00 S926 R926 3900 WHITE BALANCE S933 R933 8200 S940 R940 27k S947 DATE TIME BRIGHT S904 R904 1200 S911 R910 1500 S918 R918 2200 S925 R925 3900 S932 R932 8200 S939 R939 27k TITLE S946 FREEZE S903 R903 1200 DIGITAL EFFECT S910 R909 1500 PICTURE EFFECT ONE PUSH AF EXPOSURE COMP S917 R917 2200 POS PRESET S924 R924 3900 ONE PUSH WB INFINITY POS RESET S931 R931 8200 S938 XX R938 27k S945 XX POS1 S902 R9...

Page 17: ...SCA is a trademark of Sony Corporation 1 CD 2 RXD 3 TXD 4 DTR 5 GND 6 DSR 7 RTS 8 CTS 9 RI 1 TXD IN 2 DTR IN 3 DSR IN 4 RXD IN 5 TXD OUT 6 DTR OUT 7 DSR OUT 8 RXD OUT 9 GND 10 NC Controller D SUB 9pin Camera CN802 1 FG 2 TXD 3 RXD 4 RTS 5 CTS 6 DSR 7 GND 20 DTR Controller D SUB 25pin Camera CN802 1 TXD IN 2 DTR IN 3 DSR IN 4 RXD IN 5 TXD OUT 6 DTR OUT 7 DSR OUT 8 RXD OUT 9 GND 10 NC CONTROL METHOD...

Page 18: ...16 FCB IX47 IX47P FCB IX470 IX470P INSTALLATION To fix the camera 1 4 20UNC or 4 of M2 is used Unit mm ...

Page 19: ...17 FCB IX47 IX47P FCB IX470 IX470P ECLIPSE When designing the housing refer to the dimensional allowance as shown in the figure below ...

Page 20: ...ering etc lighting conditions Care of the unit Remove dust or dirt on the surface of the lens with a blower commercially available Other Do not apply excessive force to the printed circuit board Do not apply excessive voltage Use only the specified voltage Wear a wrist band when touching the printed circuit board This will prevent static electricity that could damage the board Use the supplied ant...

Page 21: ...2 screws Perform the random vibration test under the following conditions in the X Y and Z directions for 20 minutes in each direction The camera vibrational specification is to have no malfunction after this test Power spectrum density Effective overall value Test time 5 to 50 Hz 4 14 m2 s3 0 043 G2 Hz 50 to 100 Hz 36 dB oct 14 3 m s2 1 46 G 20 minutes ...

Page 22: ...eeze Picture Effect Digital Effect Digital Effect Level Camera Memory Clock Date Display Time Display Title Display Key Lock Camera ID Display Data Screen BackLight Back light compensation Slow Shutter Mode Shutter WB Data OnePush WB Data Manual WB Data D Zoom 1 On Wide end Auto High C000h Auto Full Auto 5 Off On Off Off Off Off Off 0 Same as the initial value setting 1998 1 1 Off Off Off Off 0000...

Page 23: ...ng One Push WB RGain setting BGain setting Zoom Tele Wide Stop Mode Power Off Power On Freeze On Focus Auto Zoom Direct Focus Direct ZmFo Direct Mem Recall Initial izing Zoom Direct D Zoom On Off Focus Far Near Stop Focus Direct Focus Auto Manual One Push AF Focus Infinity AF Sensibility High Low Focus Near Limit Camera Memory Set Reset Camera Memory Recall Zoom Focus Direct Mode transition condit...

Page 24: ... setting 3 Iris setting Gain setting Bright setting Iris Priority 1 Aperture setting Mode Power Off Power On Freeze On Initial izing ZeroLuxShot On Off IR_Light On Off LR_Reverse On Off Freeze On Off Picture Effect setting Digital Effect setting Display On Off ID Write Key Lock On Off Date Time setting Date Display On Off Time Display On Off Title setting Wide Mode 1 2 MODE CONDITIONS 1 only when ...

Page 25: ...23 Command List Ver 1 0 English ...

Page 26: ...eserves the right to change specifications of the products and discontinue products without notice Use of the RS 232C control software which is developed based upon this command list may cause malfunction or damage to hardware and software Sony Corporation is not liable for any of such damages ...

Page 27: ...s Communication speed 9600 bps Data bits 8 Start bit 1 Stop bit 1 Non parity MSB first Flow control using XON XOFF and RTS CTS etc is not supported The peripheral devices are connected in a daisy chain As shown in Fig 1 the actual internal connection is a one direction ring so that messages return to the controller via the peripheral devices The devices on the network are assigned addresses The ad...

Page 28: ...3 4 5 6 7 8 9 CD RXD TXD DTR GND DSR RTS CTS RI VISCA RS 232C VISCA Connection The camera has an interface made up of connectors for 10 pin internal wirings For an example of connection refer to the command list for each model The following shows one example Fig 2 Connection of D SUB 9 pin and FCB camera Terminal for 2nd camera Need not connected when connecting only one set ...

Page 29: ...N 1 TXD IN 2 DTR IN 3 DSR IN 4 RXD IN 5 TXD OUT 6 DTR OUT 7 DSR OUT 8 RXD OUT 9 GND 10 NC RS 232C Connection FCB CN802 RS 232C interface pin assignment 1 TXD IN Transmit Data 2 DTR IN Data Transmission Ready 3 DSR IN Data Set Ready 4 RXD IN Receive Data 5 TXD OUT Transmit Data 6 DTR OUT Data Transmission Ready 7 DSR OUT Data Set Ready 8 RXD OUT Receive Data 9 GND Ground 10 NC Controller PC Windows...

Page 30: ... 81H The packet sent to the FCB camera of address 2 is 82H In the command list as the header is 8X input the address of the FCB camera at X The header of the reply packet from the FCB camera of address 1 is 90H The packet from the FCB camera of address 2 is A0H Some of the commands for setting the FCB camera can be sent to all devices at one time broadcast In the case of broadcast the header shoul...

Page 31: ...ytes X0 6Y 02 FF Syntax Error X0 6Y 03 FF Command buffer full X0 6Y 04 FF Command cancelled X0 6Y 05 FF No socket to be cancelled X0 6Y 41 FF Command not excutable X 9 to F FCB camera address 8 Y socket number Socket number When command messages are sent to the FCB camera it is normal to send the next command message after waiting for the completion message or error message to return However to de...

Page 32: ...ding it Use the cancel message to cancel one of the two commands sent Cancel Packet Note Cancel 8X 2Y FF Y socket number X 1 to 7 FCB camera address Y socket number The Command canceled error message will be returned for this command but this is not a fault It indicates that the command has been canceled VISCA RS 232C ...

Page 33: ...rk Change X0 38 FF X 9 to F FCB camera address 8 VISCA interface command IF_Clear Clears the command buffers in the FCB camera and cancels the command being executed Command Packet Reply Packet Note IF_Clear 8X 01 00 01 FF X0 50 FF IF_Clear broadcast 88 01 00 01 FF 88 01 00 01 FF X 1 to 7 FCB camera board address For inquiry packet X 9 to F FCB camera board address 8 For reply packet VISCA interfa...

Page 34: ...xecutable 90 62 41FF Inquiry Command 81 09 04 38 FF 90 50 02 FF Completion ACK is not returned for the inquiry command Example 81 09 05 38 FF 90 60 02 FF Syntax Error Accepted non corresponding command Example Address Set 88 30 01 FF 88 30 02 FF Returned the device address to 1 IF_Clear Broadcast 88 01 00 01 FF 88 01 00 01 FF Returned the same command IF_Clear For x 8x 01 00 01 FF z0 50 FF Complet...

Page 35: ...Command Canceled z0 6y 04 FF Returned when the command executed by the specified socket is canceled by y Socket No the cancel command The completion message being executed is not returned No Socket z0 6y 05 FF Returned when no command is executed by the specified socket due to the y Socket No cancel command or when an invalid socket number is specified Command Not Executable z0 6y 41 FF Returned w...

Page 36: ... 8x 01 04 08 2p FF p Speed parameter 0 Low to 7 High 8 steps Near Variable 8x 01 04 08 3p FF Direct 8x 01 04 48 0p 0q 0r 0s FF pqrs Focus Position 1000 to C000 1 cm Auto Focus 8x 01 04 38 02 FF AF ON OFF Manual Focus 8x 01 04 38 03 FF Auto Manual 8x 01 04 38 10 FF One Push Trigger 8x 01 04 18 01 FF One push AF trigger Infinity 8x 01 04 18 02 FF Forced infinity AF Sens High 8x 01 04 58 02 FF AF sen...

Page 37: ...01 04 0B 02 FF Down 8x 01 04 0B 03 FF Direct 8x 01 04 4B 0p 0q 0r 0s FF pqrs Iris Position 0000 close to 0011 F1 4 18 steps CAM_Gain Reset 8x 01 04 0C 00 FF Gain setting Up 8x 01 04 0C 02 FF Down 8x 01 04 0C 03 FF Direct 8x 01 04 4C 0p 0q 0r 0s FF pqrs Gain Position 0000 3 dB to 0007 18 dB 8 steps CAM_Bright Reset 8x 01 04 0D 00 FF Bright setting Up 8x 01 04 0D 02 FF Down 8x 01 04 0D 03 FF Direct ...

Page 38: ...3 07 FF Stretch 8x 01 04 63 08 FF CAM_DigitalEffect Off 8x 01 04 64 00 FF Digital effect setting Still 8x 01 04 64 01 FF Flash 8x 01 04 64 02 FF Lumi 8x 01 04 64 03 FF Trail 8x 01 04 64 04 FF Effect Level 8x 01 04 65 pp FF pp Effect level 00 to 18 CAM_Memory Reset 8x 01 04 3F 00 0p FF p Memory number 0 to 5 Set 8x 01 04 3F 01 0p FF Recall 8x 01 04 3F 02 0p FF CAM_Display On 8x 01 04 15 02 FF Displ...

Page 39: ...8x 01 04 73 01 mm nn pp mnpqrstuvw Setting of display characters qq rr ss tt uu vv ww FF 1st to 10th character Title Set3 8x 01 04 73 02 mm nn pp mnpqrstuvw Setting of display characters qq rr ss tt uu vv ww FF 11th to 20th character Title Clear 8x 01 04 74 00 FF Title setting clear On 8x 01 04 74 02 FF Title display ON OFF Off 8x 01 04 74 03 FF CAM_KeyLock Off 8x 01 04 17 00 FF Key lock ON OFF On...

Page 40: ...50 00 FF Full Auto y0 50 03 FF Manual y0 50 0A FF Shutter Priority y0 50 0B FF Iris Priority y0 50 0C FF Gain Priority y0 50 0D FF Bright y0 50 1A FF Shutter Auto y0 50 1B FF Iris Auto y0 50 1C FF Gain Auto CAM_SlowShutterModeInq 8x 09 04 5A FF y0 50 02 FF Auto y0 50 03 FF Manual CAM_ShutterPosInq 8x 09 04 4A FF y0 50 0p 0q 0r 0s FF pqrs Shutter Position CAM_IrisPosInq 8x 09 04 4B FF y0 50 0p 0q 0...

Page 41: ... 8x 09 04 64 FF y0 50 00 FF Off y0 50 01 FF Still y0 50 02 FF Flash y0 50 03 FF Lumi y0 50 04 FF Trail CAM_DigitalEffectLevelInq 8x 09 04 65 FF y0 50 pp FF pp Effect Level CAM_MemoryInq 8x 09 04 3F FF y0 50 0p FF p Memory number last operated CAM_DisplayModeInq 8x 09 04 15 FF y0 50 02 FF On 8x 09 06 06 FF y0 50 03 FF Off CAM_KeyLockInq 8x 09 04 17 FF y0 50 00 FF Off y0 50 02 FF On CAM_IDInq 8x 09 ...

Page 42: ... 2 1 0 7 0 6 0 5 0 Packet 4 0 4 3 Zoom Position LH 2 1 0 FCB IX Series Block Inquiry Command List Lens control system inquiry command 1 2 Command Packet 8x 09 7E 7E 00 FF Inquiry Packet 7 0 6 0 5 0 Packet 4 0 5 3 Zoom Position LL 2 1 0 7 0 6 0 5 0 Packet 4 0 6 3 Focus Near Limit H 2 1 0 7 0 6 0 5 0 Packet 4 0 7 3 Focus Near Limit L 2 1 0 7 0 6 0 5 0 Packet 4 0 8 3 Focus Position HH 2 1 0 7 0 6 0 5...

Page 43: ...0 6 0 5 0 Packet 4 0 13 3 0 2 AF Sens 1 High 0 Low 1 Digital Zoom 1 On 0 Off 0 Focus Mode 1 Auto 0 Manual 7 0 6 0 5 0 Packet 4 0 14 3 0 2 Camera Memory Recall 1 Executing 0 Stopped 1 Focus Command 1 Executing 0 Stopped 0 Zoom Command 1 Executing 0 Stopped COMMAND LIST Lens control system inquiry command 2 2 Command Packet 8x 09 7E 7E 00 FF Inquiry Packet 7 1 Terminator FFh 6 1 5 1 Packet 4 1 15 3 ...

Page 44: ...ol system inquiry command 1 2 Command Packet 8x 09 7E 7E 01 FF Inquiry Packet 7 0 6 0 5 0 Packet 4 0 5 3 B Gain L 2 1 0 7 0 6 0 5 0 Packet 4 0 6 3 0 2 WB Mode 1 0 7 0 6 0 5 0 Packet 4 0 7 3 Aperture Gain 2 1 0 7 0 6 0 5 0 Packet 4 Exposure Mode 8 3 2 1 0 7 0 6 Gain Command 1 Valid 0 Invalid 5 Iris Command 1 Valid 0 Invalid Packet 4 Shutter Command 1 Valid 0 Invalid 9 3 Bright Command 1 Valid 0 Inv...

Page 45: ...et COMMAND LIST 7 0 6 0 5 0 Packet 4 Shutter Position 10 3 2 1 0 7 0 6 0 5 0 Packet 4 0 11 3 Iris Position 2 1 0 7 0 6 0 5 0 Packet 4 0 12 3 0 2 Gain Position 1 0 7 0 6 0 5 0 Packet 4 Bright Position 13 3 2 1 0 7 0 6 0 5 0 Packet 4 0 14 3 Exposure Comp Position 2 1 0 7 1 Terminator FFh 6 1 5 1 Packet 4 1 15 3 1 2 1 1 1 0 1 ...

Page 46: ...e 1 On 0 Off 1 Wide 16 9 Full 1 On 0 Off 0 Wide Cinema 1 On 0 Off 7 0 6 0 5 0 Packet 4 0 4 3 Title Display 1 On 0 Off 2 Display 1 On 0 Off 1 Time Display 1 On 0 Off 0 Date Display 1 On 0 Off Other inquiry commands 1 2 Command Packet 8x 09 7E 7E 02 FF Inquiry Packet 7 0 6 0 5 0 Packet 4 0 5 3 0 2 Picture Effect Mode 1 0 7 0 6 0 5 0 Packet 4 0 6 3 0 2 Digital Effect Mode 1 0 7 0 6 0 5 0 Packet 4 Dig...

Page 47: ...6 0 5 0 Packet 4 0 10 3 Camera ID LH 2 1 0 7 0 6 0 5 0 Packet 4 0 11 3 Camera ID LL 2 1 0 7 0 6 0 5 0 Packet 4 0 12 3 0 2 Zero Lux Shot 1 Provided 0 Not provided 1 0 0 System 1 PAL 0 NTSC 7 0 6 0 5 0 Packet 4 0 13 3 0 2 0 1 0 0 0 7 0 6 0 5 0 Packet 4 0 14 3 0 2 0 1 0 0 0 7 1 Terminator FFh 6 1 5 1 Packet 4 1 15 3 1 2 1 1 1 0 1 ...

Page 48: ... F8 06 F9 6 05 F11 04 F14 03 F16 02 F19 01 F22 00 CLOSE Gain 07 18 dB 06 15 dB 05 12 dB 04 9 dB 03 6 dB 02 3 dB 01 0 dB 00 3 dB Bright 17 F1 4 18 dB 16 F1 4 15 dB 15 F1 4 12 dB 14 F1 4 9 dB 13 F1 4 6 dB 12 F1 4 3 dB 11 F1 4 0 dB 10 F1 6 0 dB 0F F2 0 dB 0E F2 4 0 dB 0D F2 8 0 dB 0C F3 4 0 dB 0B F4 0 dB 0A F4 8 0 dB 09 F5 6 0 dB 08 F6 8 0 dB 07 F8 0 dB 06 F9 6 0 dB 05 F11 0 dB 04 F14 0 dB 03 F16 0 d...

Page 49: ...lower 1 byte is fixed at 00 R B Gain Aperture Digital Effect Level Others 00 to FF 00 to 0F 00 to 18 Title setting Title characters Table of character codes 00 01 B 02 C 03 D 04 E 05 F 06 G 07 H A 08 09 J 0a K 0b L 0c M 0d N 0e O 0f P I 10 11 R 12 S 13 T 14 U 15 V 16 W 17 X Q 18 19 Z 1a 1b 1c 1d 1e 1 1f 2 Y 20 21 4 22 5 23 6 24 7 25 8 26 9 27 0 3 28 29 È 2a Ì 2b Ò 2c Ù 2d Á 2e É 2f Í À 30 31 Ú 32 ...

Page 50: ...48 FCB IX47 IX47P FCB IX470 IX470P MEMO ...

Page 51: ...Sony reserves the right to change specifications of the products and discontinue products without notice ...

Page 52: ...eal 75831 Paris Cedex 17 France Tel 33 1 40 87 35 11 Fax 33 1 40 87 35 17 Germany Hugo Eckener Str 20 50829 Koln Tel 49 221 5966 322 Fax 49 221 5966 491 France 15 rue Floreal 75831 Paris Cedex 17 Tel 33 1 49 45 41 62 Fax 33 1 47 31 13 57 UK The Heights Brooklands Weybridge Surrey KT13 0XW Tel 44 990 331122 Fax 44 1932 817011 Nordic Per Albin Hanssons vag 20 S 214 32 Malmo Sweden Tel 46 40 190 800 ...