Command List
FCB-EH6500(GB) A-EEP-100-11(1)
VISCA Camera-Issued Messages
ACK/Completion Messages
Command Messages
Comments
ACK
z0 4y FF
(y:Socket No.)
Returned when the command is accepted.
Completion
z0 5y FF
(y:Socket No.)
Returned when the command has been executed.
z = Device a 8
Error Messages
Command Messages
Comments
Syntax Error
z0 60 02 FF
Returned when the command format is different or when a command with illegal
command parameters is accepted.
Command Buffer Full
z0 60 03 FF
Indicates that two sockets are already being used (executing two commands) and the
command could not be accepted when received.
Command Canceled
z0 6y 04 FF
(y:Socket No.)
Returned when a command which is being executed in a socket specified by the cancel
command is canceled. The completion message for the command is not returned.
No Socket
z0 6y 05 FF
(y:Socket No.)
Returned when no command is executed in a socket specified by the cancel command,
or when an invalid socket number is specified.
Command Not Executable
z0 6y 41 FF
(y:Socket No.)
Returned when a command cannot be executed due to current conditions. For example,
when commands controlling the focus manually are received during auto focus.
Network Change Message
Command Message
Comments
Network Change
z0 38 FF
Issued when power is being routed.
Summary of Contents for FCBEH6500
Page 1: ... 2012 Sony Corporation Color Camera Module FCB EH6500 A EEP 100 11 1 Technical Manual ...
Page 57: ...57 Specifications DIGITAL Image Output Y Cb Cr 4 2 2 FORMAT Color coding complies with BT709 ...
Page 59: ...59 Specifications 1080p 30 Output Timing Chart 1080p 25 Output Timing Chart ...
Page 60: ...60 Specifications 720p 60 Output Timing Chart 720p 50 Output Timing Chart ...
Page 61: ...61 Specifications 720p 30 Output Timing Chart 720p 25 Output Timing Chart ...