20
KD-30XS955/34XBR960/34XS955/36XS955
KD-30XS955/34XBR960/34XS955/36XS955
CRT GROUND WIRE CAUTION POINT (KD-34XBR960 ONLY)
!
* Make sure DGC tension Cable (p/n:1-900-803-55)
does NOT cross over Tension Spring (p/n:4-065-852-01)!!
* Tension spring must NOT touch LCC Coils!
* CRT Ground Wire is CENTERED (as best as possible) upon
installation (so spring will not touch LCC Coil).
* DGC Tension Cable is CENTERED (as best as possible) upon
Installation (so that cable does not touch spring).
LCC Coil
LCC Coil
CRT Ground Wire
34XBR: 1-900-808-04
DGC Tension Cable
p/n: 1-900-803-55
2-Loops for 34XBR
DGC
DGC
REV-1
6/28/04
OK INSTALLATION w/ Countermeasure
Himelon Tape
p/n: 4-079-129-21
Center Tape over the
END of the tension spring.
Himelon Tape
p/n: 4-079-129-21
Center Tape over the
END of the tension spring.
Rev.1
6/28/04
CRT BRKT X2
p/n: 4-093-523-XX (34XBR)
North-South Coil (N-S)
1-424-695-11 (34XBR)
!
Make sure wires are routed
on the OUTSIDE of CRT
Support Bracket.
!
CAUTION:
Make sure direction of lead wires is
COUNTER-CLOCK-WISE!
DIRECTION OF LEAD WIRES
NOTE:
Thicker taping of N-S Coil
is clipped to Beznet Here.
N-S COIL WIRE DRESSING CAUTION POINT (KD-34XBR960 ONLY)
Summary of Contents for FD Trinitron WEGA Hi-Scan KD-34XS955
Page 215: ......
Page 219: ......
Page 222: ...15 SETUP Setup SETUP SETUP SETUP SETUP Rear Panel 3 4 1 2 5 6 7 8 9 q qa qs ...
Page 253: ......
Page 299: ......
Page 317: ......
Page 329: ......
Page 333: ......
Page 342: ......
Page 347: ...13 SETUP Setup SETUP SETUP SETUP SETUP Rear Panel 3 4 1 2 5 6 7 8 9 q qa ...
Page 378: ......
Page 428: ......