— 16 —
KV-13FM12/13FM13/13FM14/14FM12/14FM12A/14FM12C/14FM14
3-2. CONVERGENCE
Before starting convergence adjustments:
1. Perform FOCUS, V.LIN AND V.SIZE adjustments.
2. Set BRIGHTNESS control to minimum.
3. Feed in dot pattern.
Vertical Static Convergence
1. Adjust V.STAT magnet to converge red, green and blue dots in
the center of the screen (Vertical movement adjust V.STAT RV
to converge).
B
G
R
Center dot
R G B
V.STAT magnet
RV701 V.STAT
2. Tilt the V.STAT magnet and adjust static convergence to open
or close the V.STAT magnet.
When the V.STAT magnet is moved in the direction of arrows a
and b, red, green, and blue dots move as shown below:
a
b
b
B
G
R
a
b
B
G
R
a
B
G
R
R
G
B
b
R
G
B
b
b
a
R
G
B
(1)
(3)
(2)
Horizontal Static Convergence
If the blue dot does not converge with the red and green dots,
perform the following:
1. Move BMC magnet (a) to correct insufficient H. Static
convergence.
2. Rotate BMC magnet (b) to correct insufficient V. Static
convergence.
3. After adjusting the BMC magnet, repeat Beam Landing
Adjustment.
b
BMC magnet
BMC MA
GNET
PURITY
V-STAT
Dynamic Convergence Adjustment
Before performing this adjustment, perform Horizontal
and Vertical Static Convergence Adjustment.
1. Slightly loosen deflection yoke screw.
2. Remove deflection yoke spacers.
3. Move the deflection yoke for best convergence
as shown on the following page.
Summary of Contents for FD TRINITRON WEGA KV-13FM12
Page 26: ... 26 KV 13FM12 13FM13 13FM14 14FM12 14FM12A 14FM12C 14FM14 NOTES ...
Page 36: ......
Page 50: ... 65 KV 13FM12 13FM13 13FM14 14FM12 14FM12A 14FM12C 14FM14 NOTES ...
Page 51: ... 66 KV 13FM12 13FM13 13FM14 14FM12 14FM12A 14FM12C 14FM14 NOTES ...
Page 52: ... 67 KV 13FM12 13FM13 13FM14 14FM12 14FM12A 14FM12C 14FM14 ...