38
–
KF-60DX100
RM-Y910
H POS SHI
No.
Name
0
VAR POS-CTL
Table select
0 - 15
Table 1
1
D-GM HP
Position control shift
0 - 15
Table 1
Item
Function
Data
Range
Data
Table 1
0
VAR POS-CTL=
0
1
2
3
4
5
6
7
1
D-GM HP
9
9
8
8
7
7
6
6
0
VAR POS-CTL=
8
9
10
11
12
13
14
15
1
D-GM HP
11
11
10
10
11
11
10
10
SH SET
No.
Name
0
SH
Table select
0 - 6
Table 1
1
SHIFT SET
Position control shift model select
0 - 31
Table 1
Item
Function
Data
Range
Data
Table 1
0
SH=
0
1
2
3
4
5
6
7
1
SHIFT SET
15
16
17
18
16
16
16
16
LCD-DR
No.
Name
0
FRP CNT
FR pulse control
0 - 1
0
1
R VCOM (*1)
V COM adjustment (R)
0 - 255
127
2
R ODD VR
ODD adjustment (R)
0 - 255
50
3
R EVEN VR
EVEN adjustment (R)
0 - 255
50
4
R DLY CNT
DELAY control (R)
0 - 255
127
5
R DA VSET (*1)
D/A voltage set (R)
0 - 255
220
6
G VCOM (*1)
V COM adjustment (G)
0 - 255
127
7
G ODD VR
ODD adjustment (G)
0 - 255
50
8
G EVEN VR
EVEN adjustment (G)
0 - 255
50
9
G DLY CNT
DELAY control (G)
0 - 255
127
10
G DA VSET (*1)
D/A voltage set (G)
0 - 255
220
11
B VCOM (*1)
V COM adjustment (B)
0 - 255
127
12
B ODD VR
ODD adjustment (B)
0 - 255
105
13
B EVEN VR
EVEN adjustment (B)
0 - 255
105
14
B DLY CNT
DELAY control (B)
0 - 255
127
15
B DA VSET (*1)
D/A voltage set (B)
0 - 255
195
16
R VREF SEL
Voltage ref select (R)
0 - 1
0
17
G VREF SEL
Voltage ref select (G)
0 - 1
0
18
B VREF SEL
Voltage ref select (B)
0 - 1
0
*1: Adjustable, but not used on service.
Item
Function
Data
Range
Data
LM75
(TEMP)
No.
Name
0
SET
Temperature switching to maximum velocity of wind
0 - 99
42 DEC
1
TIME
Time to keep maximum velocity of wind and to detect
0 - 99
10 MIN
OSD-E
No.
Name
0
VPOS
Engine service indication V position
0 - 255
8
1
HPOS
Engine service indication H position
0 - 255
22
OPTION-E
No.
Name
0
LAMP TIME
Lamp lighting time
0
1
LAMP OFF
Time from power off to lamp off (0 : 0 sec, 1 : 5 sec)
0 - 255
1
2
FAN OFF
Time to FAN stop (0 : 2 min, 1 : 2 min)
0 - 255
0
3
FAN1 RPM1
Rotating speed of FAN for optics on normal condition
0 - 3
2
4
FAN1 RPM2
Rotating speed of FAN for optics after power off
0 - 3
2
5
FAN2 RPM1
Rotating speed of FAN for lamp on normal condition
0 - 3
1
6
FAN2 RPM2
Rotating speed of FAN for lamp after power off
0 - 3
1
7
FLAG1
Not used on service
0 - 255
0
8
AGING PT
Not used on service
0 - 255
0
9
TEMP SHIFT
Temperature shift for LCD panel drive
0 - 255
1
10
ADJ
Not used on service
0 - 1
0
11
P CTL SHT1
LCD panel age-based change (position control) correction 1
0 - 255
10
12
P CTL SHT2
LCD panel age-based change (position control) correction 2
0 - 255
60
Item
Function
Data
Range
Data
Item
Function
Data
Range
Data
Item
Function
Data
Range
Data
OP
No.
Name
0
DLY1
Power on to relay timing = DLY1 x 50ms
0 - 15
4
1
DLY2
Power on mute timing = DLY2 x 50ms
0 - 31
12
2
DLY3
Relay on to start bus communication
0 - 15
7
3
AGC
0 - 255
255
4
RAMW
0 - 1
0
ID
No.
Name
0
ID0
Selection of OSD languages & color system
0 - 255
89
1
ID1
Selection of composite & S-Video inputs
0 - 255
127
2
ID2
Selection of audio related controls
0 - 255
239
3
ID3
Selection of basic system settings
0 - 255
98
4
ID4
Selection of basic system settings
0 - 255
203
5
ID5
Selection of advanced system settings
0 - 255
177
6
ID6
Selection of sub picture related settings
0 - 255
54
7
ID7
Selection of some reserved settings
0 - 255
24
Item
Function
Data
Range
Data
Item
Function
Data
Range
Data