24
HCD-C5
[Factory Preset Mode]
∗
This mode clears all data including preset data stored in the
RAM to initial conditions. Excute this mode when returning
the set to the customer.
Procedure:
1. Press the
?/1
button to turn the power on.
2. Press the
FUNCTION
z
button to set the CD function.
(except the TUNER function)
3. Press three buttons
VOL +
,
CD
Z
and
MD
Z
simultaneously.
4. The message “COLD RESET” blinks and the present contents
are reset to the default values.
[Version and Destination Display Mode]
∗
The version or destination is displayed.
Procedure:
1. Press the
?/1
button to turn the power on.
2. To enter the test mode, press the three buttons
VOL +
,
x
and
MD
Z
simultaneously.
3. The model and destination are displayed.
4. Press the
REC/REC IT/NORMAL
and
u
buttons simul-
taneously.
5. The version is displayed as “STR/CD V . ”.
6. Press the
REC/REC IT/NORMAL
and
u
buttons simul-
taneously.
7. The version is displayed as “MD V . ”.
8. Press the
REC/REC IT/NORMAL
and
u
buttons simul-
taneously, then the mode returns to step 3.
9. To exit from this mode, press the
?/1
button to turn the
power off.
[FL Tube Test Mode]
∗
All fluorecent segments and LEDs are tested.
Procedure:
1. Press the
?/1
button to turn the power on.
2. To enter the test mode, press three buttons
VOL +
,
x
and
./m
TUNING -
simultaneously.
3. All segments and LEDs are turned on.
4. Press the
REC/REC IT/NORMAL
and
u
buttons simul-
taneously.
5. All segments are turned off (All LEDs still lit).
6. Press the
REC/REC IT/NORMAL
and
u
buttons simul-
taneously.
7. Almost half segments are turned on. (PATTERN 1)
8. Press the
REC/REC IT/NORMAL
and
u
buttons simul-
taneously.
9. The segments which are turned on in step 7 are turned off,
then remaining segments are turned on. (PATTERN 2)
10. Press the
REC/REC IT/NORMAL
and
u
buttons simul-
taneously, the mode returms to step 3 and all segments are
turned on.
11. To exit from this mode, press the
?/1
button to turn the
power off.
[Key Test Mode]
∗
Keyboard check.
Procedure:
1. Press the
?/1
button to turn the power on.
2. To enter the test mode, press three buttons
VOL +
,
x
and
>/M
simultaneously.
3. In the key test mode, the fluorecent indicator displays
“KEY00”.
4. Each time a button is pressed, “KEY ” value increases.
However, once a button is pressed, it is no longer taken into
account.
5. To exit from this mode, press three buttons simultaneously as
step 2 , or disconnect the power cord.
[Amp Test Mode]
Procedure:
1. Press the
?/1
button to turn the power on.
2. Press three buttons
VOL -
,
CD
Z
and
MD
Z
simulta-
neously.
3. Press two buttons
REC/REC IT/NORMAL
and
x
simulta-
neously.
4. The message “7 [TESTMIN]” is displayed for a few seconds.
5. Press two buttons
REC/REC IT/NORMAL
and
x
simulta-
neously again.
6. Each time two buttons are depressed, the display changes as
“8 [TESTMID]” , “9 [TESTMAX]”, and “10 [TESTSUR]” .
7. Press the
VOL +
button, the display changes “VOLUME 21”
to “VOLUME MAX”.
8. Press the
VOL -
button, the display changes “VOLUME 21”
to “VOLUME MIN”.
9. To exit from this mode, press the
?/1
button to turn the
power off and cold reset is executed.
[CD Test Mode]
∗
The CD system versions are displayed.
Procedure:
1. Press the
?/1
button to turn the power on.
2. Press the
FUNCTION
z
button to set the CD function.
3. Press three buttons of
VOL +
,
x
and
CD SYNC HIGH
simultaneusly.
4. The message “dut CD VER” is displayed.
5. Press the
CD
Z
button and the version “CD . ” is dis-
played.
6. Press the
>/M
button and “CDSYS ”
is displayed.
7. Each time the
>/M
button is depressed ,
the display changes as “CDMA S”, “CDBD O”, “CDCD M”.
8. By depressing the
./m
TUNING -
button the versions
are displayed in reverse.
9. To exit this mode, press the
?/1
button to turn the power off.
SECTION 4
TEST MODE