16. AUTO GAIN CONTROL OUTPUT LEVEL ADJUSTMENT
Be sure to perform this adjustment when the optical pick-up is replaced.
If the adjustment results becomes “Adjust NG!”, the optical pick-up may be faulty or the servo system circuits may be abnormal.
16-1. CD Auto Gain Control Output Level Adjustment
Procedure:
1. Load the check disc (TDYS-1).
2. Press the
. m
“R”
or
M >
“R”
button to display “AG Set (CD)” (C11).
3. When the
ENTER/YES “R”
button is pressed, the adjustment will be performed automatically.
“Complete!” will then be displayed momentarily when the value is recorded in the non-volatile memory, after which the
display changes to “AG Set (CD)” (C11).
4. Press the
MD
Z
button and take out the check disc.
16-2. MO Auto Gain Control Output Level Adjustment
Procedure:
1. Load the test disc (MDW-74/GA-1).
2. Press the
.
“R”
or
>
“R”
button to display “AG Set (MO)” (C10).
3. When the
ENTER/YES “R”
button is pressed, the adjustment will be performed automatically.
“Complete!” will then be displayed momentarily when the value is recorded in the non-volatile memory, after which the
display changes to “AG Set (MO)” (C10).
4. Press the
MD
Z
button and take out the test disc.
Adjustment and checking Loacation:
Note:
It is useful to use the jig for checking the waveform. (Refer to Servicing Notes on page 6)