21
HCD-DZ110/DZ111/DZ120/DZ120K
8-4. EMERGENCY HISTORY
To check the emergency history, please follow the following
procedure.
(1) From the Top Menu of Remocon Diagnosis Menu, select “3.
Emergency History Check” by pressing the 3 “R” button on
the remote commander. The following screen appears on the
on-screen display.
(2) You can check the total time when the laser is turned on during
playback of DVD and CD from the above menu. The maximum
time, which can be displayed are 999h 59min.
(3) You can check the error code of latest 10 emergency history
from the above menu. To view the previous or next page of
emergency history, press
.
“R” or
>
“R” on the remote
commander. The error code consists of the following three
blocks. The first block indicates the error code. The second
block indicates the parameter and the third block indicates the
time of error code as shown below.
• Error Code
*1 : Error Code
*2 : Parameter of error code
*3 : Time of error code
Emg.History Check
1. 01 05 04 04
Laser Hours
CD
999h
59min
DVD
999h
59min
00 92 46 00
00 00 00 00
00 00 23 45
2. 02 02 01 01
00 A9 4B 00
00 00 00 00
00 00 23 45
Next Next Page Prev Prev Page
O Return to Top Menu
Ver. 1.4
Emg.History Check
1. 01 05 04 04
Laser Hours
CD
999h
59min
DVD
999h
59min
00 92 46 00
00 00 00 00
00 00 23 45
2. 02 02 01 01
00 A9 4B 00
00 00 00 00
00 00 23 45
Next Next Page Prev Prev Page
O Return to Top Menu
*
1
*
2
*
3
The meaning of error code is as below:
01: Communication error (No reply from syscon)
02: Syscon hung up
03: Power OFF request when syscon hung up
19: Thermal shutdown
24: MoveSledHome error
25: Mechanical move error (5 Changer)
26: Mechanical move stack error
30: DC motor adjustment error
31: DPD offset adjustment error
32: TE balance adjustment error
33: TE sensor adjustment error
34: TE loop gain adjustment error
35: FE loop gain adjustment error
36: Bad jitter after adjustment
40: Focus NG
42: Focus layer jump NG
52: Open kick spindle error
51: Spindle stop error
60: Focus on error
61: Seek fail error
62: Read Q data/ID error
70: Lead in data read fail
71: TOC read time out (CD)
80: Can’t buffering
81: Unknown media type
8-4-1. Clear the Laser Hour
Press DISPLAY “R” button and then press CLEAR “R” button.
The data for both CD and DVD data are reset.
Emg.History Check
1. 01 05 04 04
Laser Hours
CD
0h
0min
DVD
0h
0min
00 92 46 00
00 00 00 00
00 00 23 45
2. 02 02 01 01
00 A9 4B 00
00 00 00 00
00 00 23 45
Next Next Page Prev Prev Page
O Return to Top Menu
Emg.History Check
1. 00 00 00 00
Laser Hours
CD
999h
59min
DVD
999h
59min
00 00 00 00
00 00 00 00
00 00 00 00
2. 00 00 00 00
00 00 00 00
00 00 00 00
00 00 00 00
Next Next Page Prev Prev Page
O Return to Top Menu
8-4-2. Clear the Emergency History
Press TOP MENU “R” button and then press CLEAR “R” button.
The error code for all emergency history would be reset.
8-4-3. Clear the Initialize Setup Data
Press MENU “R” button and then press CLEAR “R” button on
the remote commander.