6-9.
SCHEMATIC DIAGRAM – POWER Board –
• Voltages are dc with respect to ground under no-signal
conditions.
no mark : TUNER (FM/AM)
6.2
6.7
7.9
0.6
0
0.5
1.1
1.1
0.7
1.1
MAIN BOARD
(2/2)
CN304
E
CN402
6P
B GND
+
C404 0.022
C402 0.022
+
C408 0.022
C406 0.022
TR401
POWER
TRANSFORMER
MTZJ-6.8B
+
+
+
Q404
+6V REGULATOR
+
Q401–403
POWER ON/OFF
RELAY DRIVE
TR402
POWER
TRANSFORMER
2.2k
C421 0.001 250V
RL401
AC IN
POWER BOARD
2SD1616-L
2SD1616-L
2.2k
(Page 15)
The components identified by mark
0
or dotted
line with mark
0
are critical for safety.
Replace only with part number specified.