HCD-HDX285/HDX287WC/HDX585/HDX587WC/HDX589W/HDX685/HDX686W
24
VERSION DISPLAY
This mode displays the version of the STR/DVD micro controller.
Note:
Not used for the servicing.
AUTOMATIC ACOUSTIC FIELD CALIBRATION MICRO-
PHONE TEST MODE
Procedure:
1. Press the [
?
/
1
] button to turn the power on.
2. Insert ECM-AC2 supplied as an accessory into the AUDIO IN/
A.CAL MIC jack.
3. While pressing the [
x
] and [
Z
] buttons simultaneously, turn
the [VOLUME] dial in the direction of (–).
4. Con
fi
rm that the following are shown on the display panel.
1
The jack inserted/non-inserted detection display and the
STEREO/MONO detection display.
2
Presence of DIGITAL voice input to the microcomputer.
(OK: input, NG: no input)
3
The value of the MIC input to the micro controller. (shown
“255h”)
* * *
* *
* * *
1
2
3
1
“NON” : Not detected
“ST”
: STEREO
“MN” : MONO
2
OK : input
NG : no input
3
0-255 (Changes in real time)
5. To exit this mode, press two buttons [
x
] and [
Z
] simultane-
ously, turn the [VOLUME] dial in the direction of (–).
DEMO PLAY OUT
It is a mode to release the demonstration reproduct by the dedi-
cated demonstration disc.
Procedure:
1. During playback the DEMO disc, press the [
x
] and [
N
] but-
tons for
fi
ve seconds simultaneously.
2. The message “DEMO OFF” is displayed, a mode to reproduct
the demonstration is released.
AMP TEST MODE
The examination of the AMP measurement safety standard/tem-
perature characteristic modes can be easily executed by executing
this mode in a short time.
Procedure:
1. Press the [
?
/
1
] button to turn the power on.
2. Press three buttons [
x
], [
N
] and [
Z
] simultaneously.
3. The message “MEASURE” is displayed on the
fl
uorescent in-
dicator tube and enter the AMP measurement mode.
4. When the [DISPLAY] button on the remote commander is
pressed in the state of step 3, the message “SAFETY” is dis-
played on the
fl
uorescent indicator tube and enter the AMP
safety standard/temperature characteristic mode.
5. When the [MUTING] button on the remote commander is
pressed in the state of step 3, the message “VOL N” is dis-
played on the
fl
uorescent indicator tube.
6. When the [MUTING] button on the remote commander is
pressed in the state of step 5, the message “VOL M/M” is
displayed on the
fl
uorescent indicator tube and enter the vol-
ume MIN/MAX mode. In this mode, the message “VOLUME
MAX” is displayed on the
fl
uorescent indicator tube when
[] button on the remote commander is pressed,
and the message "VOLUME MIN” is displayed on the
fl
uores-
cent indicator tube when [VOLUME –] button on the remote
commander is pressed.
7. To exit from this mode, press the [
?
/
1
] button. The message
“COLD RESET” is displayed on the
fl
uorescent indicator tube
for a while and all the settings are reset.
PROTECTION FACTOR (SD DETECTION/DC DETEC-
TION) IDENTIFICATION TEST MODE
When an error is detected, the
fl
orescent indicator tube alternately
displays
“PROTECTOR”
h
“PUSH POWER”.
Press
the
[
?
/
1
] button.
* Buttons other than the [
?
/
1
] button are invalid.
“STANDBY” blinks three times on the
fl
orescent indicator tube.
The protection release state (POWER OFF) is established.
(No
fl
orescent indicator tube display)
Press
the
[
?
/
1
] button twice.
The power to the system turns on, and the normal operation is es-
tablished. (Restore)
During the protection state:
1. If the AC plug is connected or disconnected during the protec-
tion state, the protection state is released, and the normal op-
eration is established. (The protection state is not maintained)
2. The protection factor is displayed by pressing the button on
the remote commander in order of [RETURN]
→
[3]
→
[2]
→
[0]
→
[0]
→
[ANGLE] during the protection state. (during the
“PROTECTOR”
h
“PUSH POWER” display)
When SD is detected: Repeats
“SD
DETECT”
h
“PUSH POWER”.
When DC is detected: Repeats
“DC
DETECT”
h
“PUSH POWER”.
SD detection:
When the “L” output from the SD (shutdown) port on the
S-MASTER POWER Driver Shutdown and voltage descent
(15V or less) of 30V power supply (PVDD) are detected.
DC detection:
When the “L” output from the power/speaker error detection
circuit (DC detection port) is detected for two seconds continu-
ally, the power system other than that of the
fl
orescent indica-
tor tube is turned off, and the protection state is established.
COLOR SYSTEM CHANGE (HDX285: 240V AC area in E
and Saudi Arabia models only)
This mode let you change the color system of the video output
from PAL to NTSC or vice-versa.
Procedure:
1. Press the [
?
/
1
] button to turn the power on.
2. Press the [FUNCTION] button to select the “DVD”.
3. Press the [
?
/
1
] button to turn the power off.
4. Press two buttons [
.
] and [
?
/
1
] simultaneously.
5. The message “COLOR PAL” or “COLOR NTSC” will be dis-
played on the
fl
uorescent indicator tube and color system of the
video output is changed.