3
ITEMS OF ERROR HISTORY MODE ITEMS AND CONTENTS
Display
Details of History
op rec tm
Displays the recording time.
Displayed as “r
ssssss
h”.
The displayed time is the total time the laser is set to the high power state.
This is about 1/4 of the actual recording time.
The time is displayed in decimal digits from 0h.
op play tm
Displays the playback time.
Displayed as “p
ss
min”. The displayed time is the total of the actual play time.
spdl rp tm
Displays the spindle motor running time.
Displayed as “r
ssssss
h”.
The time is displayed in decimal digits from 0h.
retry err
Displays the total number of retries during recording and number of retry errors during play.
Displayed as “r
ss
p
ss
”.
“r” indicates the retries during recording while “p” indicates the retry errors during play.
The number of retries and retry errors are displayed in hexadecimal digits from 00 to FF.
total err
Displays the total number of errors.
Displayed as “total
ss
”.
The number of errors is displayed in hexadecimal digits from 00 to FF.
err history
Displays the 10 latest errors.
Displayed as “0
s
ErrCd @@”.
s
indicates the history number. The smaller the number, the more recent is the error. (00 is the latest)
@@ indicates the error code.
Refer to the following table for the details. The error history can be switched by pressing the
. m
“R”
or
M >
“R”
button.
retry adrs
Display the 5 latest retry address.
Display as “
ss
ADRS@@@@”.
ss
indicates the history number. The smaller the number, the more recent is the error. (00 is the latest)
@@@@ indicates the cluster of retry address.
The number of retry address can be switched by pressing the
. m
“R”
or
M >
“R”
button.
er refresh
Mode to clear the error history and retry address history.
Procedure:
1) Press the
[REC MODE]
button.
2) The display will change to “er refresh?”, and then press the
ENTER/YES “R”
button.
The operation is over if “Complete!” is displayed.
After this mode was executed, check the following:
• The data have been cleared.
• Perform the recording and playing to check that the mechanism operates normally.
tm refresh
Mode to clear cumulative time of “op rec tm” and “op play tm”.
Procedure:
1) Press the
[REC MODE]
button.
2) The display will change to “tm refresh?”, and then press the
ENTER/YES “R”
button.
The operation is over if “Complete!” is displayed.
op change
Mode to clear cumulative time of “op rec tm” and “op play tm”.
These historical data are used to determine the timing when the optical pick-up is to be replaced. When the
optical pick-up was replaced, perform this operation to clear historical data.
Procedure:
1) Press the
[REC MODE]
button.
2) The display will change to “op change?”, and then press the
ENTER/YES “R”
button.
The operation is over if “Complete!” is displayed.
spdl change
Mode to clear cumulative time of “spdl rp tm”.
This historical data is used to determine the timing when the spindle motor is to be replaced. When the spindle
motor was replaced, perform this operation to clear historical data.
Procedure:
1) Press the
[REC MODE]
button.
2) The display will change to “spdl change?”, and then press the
ENTER/YES “R”
button.
The operation is over if “Complete!” is displayed.