CAPACITOR DISCHARGE FOR ELECTRIC SHOCK PREVENTION
Switching Regulator Board (Conductor side view) (HCD-SHAKEX7)
In checking the Switching Regulator board, make 4 capacitors discharge of C18, C20, C27 and C28 for eletrical shock prevention.
800
:
/5 W
R
R
800
:
/5 W
C28
R
800
:
/5 W
R
800
:
/5 W
C27
C18