6
HCD-ZX10D
DECISION TO PASS OR FAIL OF THE OPTICAL PICK-UP
BLOCK
Connection:
1. Connect an oscilloscope to test point
1
pin and
3
pin of
3. Put the disc (LUV-P01) (Part No. 4-999-032-01) (CD) in to
4. Confirm that oscilloscope waveform is clear and check RF
signal level is correrect or not.
5. Put the disc (TDV-520CSO) (Part No. J-2501-236-A) (DVD)
6. Perform Comfirmation in the same manner as step 4.
A clear RF signal waveform means that the shape “
◊
” can be clearly
distinguished at the center of the waveform.
Checking Location:
– DMB07 BOARD (Component Side) –
HOW TO OPEN THE DISC TRAY WHEN POWER SWITCH TURNS OFF
2
Pull-out the disc tray.
1
Turn the gear (chuck)
in the direction of
arrow
A
.
A
+
–
oscilloscope
DMB07 board
CN901
1
pin
CN901
3
pin
RF signal waveform
VOLT/DIV: 200 mV
TIME/DIV: 500 ns
CD: 1.05
±
0.2 Vp-p
DVD: 1.09
±
0.2 Vp-p
1
7
CN901