1-3 (E)
HKDW-702
1-4. Opening and Closing the Inside
Panel
Opening the Inside Panel
n
Be sure to turn off the POWER switch, unplug the AC
power cord or remove the battery before starting the
following procedure to prevent the inside of the unit from
damage.
1.
Loosen the four screws (with drop-safe) and open the
inside panel in the direction of the arrow.
m
.
Folding the flexible card wire connected to the FP-
121 board shortens the life of the flexible card wire
significantly. Be very careful when handling the
flexible card wire not to fold it.
.
When opening the inside panel, place the unit so that
the inside panel is positioned on top of the POWER
switch.
Closing the Inside Panel
1.
Confirm that both of the right and left hinges are
engaged with the hooks of the chassis correctly.
2.
Attach the inside panel and fix it with the four screws
(with drop-safe).
n
Standard tightening torque value :
Screw (with drop-safe, B3
x
12)
0.8 N
.
m (8.0 kgf
.
cm)
n
Be careful not to pinch the harness between the inside
panel and chassis.
Flexible card wires
Inside panel
FP-121 board
Inside panel
Hook
Hinge
POWER switch
Hinge
Hook
Screw
(with drop-safe)
Screw (with drop-safe)
Screws
(with drop-safe)
1-4. Opening and Closing the Inside Panel