1-20 (E)
.
IM/HDCU1000 Series
Ref.No.
Name
Function
Factory default setting
S32
U-TALLY
Not used
TTL
(POWER/TTL)
S500
MIC1 LEV
Sets the output level of MIC.
0 dB
0dB : When the input level on the system is 0 dBu.
_
20dB: When the input level on the system is
_
20 dBu.
S501
MIC2 LEV
Sets the output level of MIC.
0 dB
0dB : When the input level on the system is 0 dBu.
_
20dB: When the input level on the system is
_
20 dBu.
S502
PGM1 IN
Sets the input level of the system PGM (analog).
0 dB
0dB : When the input level of the system is 0 dBu.
_
20dB: When the input level of the system is
_
20 dBu.
S503
PGM2 IN
Sets the input level of the system PGM (analog).
0 dB
0dB : When the input level of the system is 0 dBu.
_
20dB: When the input level of the system is
_
20 dBu.
S602
PROD SEL
Selects the intercom system of the producer line.
4W
S600
PROD SEL2
RTS
S603
ENG SEL
Selects the intercom system of the engineer line.
4W
S601
ENG SEL2
RTS
RV500
MIC1 LEV
RV501
MIC2 LEV
RV600
PROD 2WIRE CANCEL
RV601
ENG 2WIRE CANCEL
Tally system setting
U tally
Switch
S31
S32
Signal standard
POWER/
POWER/TTL
CONTACT
Contact supply
CONTACT
_
24 V power supply
POWER
POWER
5 V power supply
POWER
TTL
S602
S600
4-Wire
4W
*
RTS
RTS
RTS
Clear-Com
RTS
CC
*
When 4-Wire is selected, S600 can be set to RTS or CC.
S603
S601
4-Wire
4W
*
RTS
RTS
RTS
Clear-Com
RTS
CC
*
When 4-Wire is selected, S601 can be set to RTS or CC.