33
Menus
FILE Menu
Three types of files can be used for easy adjustments of the
camera; Operator, Scene, and Reference.
You can store the items set with the OPERATION menu and
customized USER menu in the Operator file.
For the specific items included in these files, refer to the
Maintenance Manual.
<OTHERS 1>
M16
FAN MODE
OFF,
AUTO1
, AUTO2, MIN,
MAX
AUTO1: Normal rotation
AUTO2: Slow rotation
(The internal temperature
may raise with the OFF
setting.)
CAM BARS
ON,
OFF
CAM MENU
ON,
OFF
, (OFF)
(OFF): When a camera
other than an HDC-P1
is connected
<OTHERS 2>
M17
DATE TYPE
1 Y/Mn/D, 2 Mn/D, 3 D/M/Y
4 D/M,
5 M/D/Y
, 6 M/D
Y: Year
Mn: Month (numeric)
M: Month (character
string)
D: Day
FILTER WHT
MEM
ON,
OFF
Set to ON/OFF to use
independent white
memory at each CC filter
position.
F NO. DISP
CONTROL
, RETURN
Select the iris indication
on the panel when AUTO
IRIS is off:
CONTROL: To display the
value from the camera
RETURN: To display the
value returned from the
lens
(When AUTO IRIS is on,
the value returned from
the lens is always
displayed.)
Page title
Page No.
Item
Settings
Page title
Page No.
Item
Settings / Default
<OPERATOR
FILE>
F01
READ (MS
→
CAM)
Execute by ENTER.
To read the operator file
from a “Memory Stick”
WRITE (CAM
→
MS) Execute by ENTER.
To write the current
settings of the operator
file items to a “Memory
Stick”
PRESET
Execute by ENTER.
To set the operator file
items to the preset
values in internal
memory
STORE PRESET
FILE
Execute by ENTER.
To store the current
settings of the operator
file items in the operator
file in internal memory.
FILE ID
Max.14 characters
Enter a comment for the
operator file to be written
to a “Memory Stick.”
See “Specifying a
character string” (page 25).
CAM CODE
Camera code
(display only)
DATE
Date
(display only)
<SCENE FILE>
F02
1
To store and read scene
files (paint data):
When storing a file in
camera memory, specify
the number for STORE and
execute by ENTER.
When reading, only specify
the number.
2
3
4
5
STORE
STANDARD
Execute by ENTER.
To read the standard
paint data
<REFERENCE>
F03
STORE FILE
Execute by ENTER.
To store the current
settings of the reference
file items in the
reference file in internal
memory.
STANDARD
Execute by ENTER.
To read the standard
values in the reference
file in internal memory.
ALL PRESET
Execute by ENTER.
To resume the factory-
preset reference file