No.
Name/Setting item
Function
1
Menu bar
Displays the screen name.
2
Firmware Version
Displays the firmware version of this unit.
3
CPU Temperature
Displays the temperature of CPU. (Celsius and Fahrenheit)
• ○ (C) ○ (F)
4
System Temperature
Displays the temperature of system. (Celsius and Fahrenheit)
• ○ (C) ○ (F)
5
System Fan RPM
Displays the system fan condition.
• OK: Number of rotations
• NG: Number of rotations
6
System Working time
Displays the system working time.
• ○ (H)
7
System Booting Count
Displays the system booting count.
8
HDD Working Time
Displays HDD working time.
• ○ (H)
9
HDD Status
Displays the HDD condition.
• Normal
• abnormal
10
Abnormal Shutdown Count
Displays the number of times of power off
• number of times
11
DVD Drive Working Time
(HVO-550MD only)
Displays the DVD writing laser’s cumulative period of use.
(HVO-550MD only)
• ○ (H)
12
DVD Tray Open Count (HVO-550MD
only)
Displays the tray opening count. (HVO-550MD only)
13
Remaining Battery
Displays the remaining condition of battery
• normal
• abnormal
14
Front Panel Microcom. Firmware Ver.
Display firmware version of front panel micon
15
Back button
Returns to the former screen.
5-2-6.
Obtain User Log
Saves the user’s log in USB media. When this item is selected, the message to insert the media is displayed, then insert
a USB media into USB1 and select OK.
When the saving is completed, the log file name and destination drive hierarchy is displayed. For this function, a USB
media is required.
5-2-7.
Obtain System Log
Saves the system log in USB media. When this item is selected, the message to insert the media is displayed, then insert
a USB media into USB1 and select OK. When the saving is completed, the log file name and destination drive hierarchy
is displayed. The maximum of five minutes is required to obtain the log. For this function, a USB media is required.
5-2-8.
Update Firmware
Performs the firmware update. When this item is selected, new and old version of firmware, and confirming dialogue
asking to surely update are displayed. Moreover, the version downgrading is not accepted, and a message informing the
improper update is displayed.
HVO-500MD/HVO-550MD
5-7