OVER DISP HOLD [> Hold OVER]:
Determine whether or not
to hold the OVER indicator on the audio level meters once
the indicator lights.
*
OFF [>> OFF]:
Do not hold the OVER indicator.
ON (HOLD) [>> ON]:
Hold the OVER indicator.
Note
With ON selected, once the indicator is held it will remain held
unless you change the setting to OFF.
LCD [> LCD]:
Adjust LCD
monitor display quality.
BACK LIGHT [>> BK Light]:
Set backlight brightness.
1 [>>> 1] to 12 [>>> 12]:
Larger numerical values indicate
higher brightness
Factory default setting:
*
6 [>>> 6]
GAMMA [>> GAMMA]:
Adjust the slope of the
gamma correction curve.
OFF [>>> OFF]:
No adjustment
TYPE 1 [>>> Type1]:
Set to Type 1.
*
TYPE 2 [>>> Type2]:
Set to Type 2.
ALARM [> ALARM]:
Determine whether alarm messages are
issued or not.
OFF [>> OFF]:
Alarm messages are not issued.
*
ON [>> ON]:
Alarm messages are issued.
REF ALARM [> REF ALARM]:
Determine whether alarm
messages related to the reference video signal are issued
or not.
OFF [>> OFF]:
Alarm messages are not issued.
*
ON (LIMITED) [>> ON (Limit)]:
Alarm messages are issued
only during recording mode, E-E mode, REC-pause mode,
and EDIT mode.
ON [>> ON]:
Alarm messages are issued.
TIME CODE [Time code]: Settings related to the timecode
generator
Description of settings
TC MODE [> TC mode]:
Determine the timecode to use:
internal timecode using a preset initial value, regenerated
internal timecode (locked to timecode read from tape), or
external timecode.
*
INT PRESET [>> PRESET]:
Use internal timecode with a
preset initial value.
INT REGEN [>> REGEN]:
Use internal timecode locked to
timecode read from tape.
EXT REGEN [>> EXT]:
Use external timecode selected as
follows.
• When TC is selected
External timecode input to the TC IN connector.
However, if SDI input is selected, in order to support
embedded timecode the synchronization priority
sequence is as follows.
1
LTC (SD-SDI signal: RP188 or HD-SDI signal: ARIB
STD-B4.2.0, and RP188) embedded in the SDI input
2
An Input to the TC IN connector
• When VITC is selected
The VITC timecode present in the input video signal.
1
When SD-SDI input is selected: The VITC signal
superimposed as video signal
2
When HD-SDI input is selected: The VITC signal
embedded as ANC DATA.
RUN MODE [> RUN mode]:
Select the advancement (RUN)
mode of the timecode generator.
*
FREE RUN [>> FREE RUN]:
Timecode generator keeps
running.
REC RUN [>> REC RUN]:
Timecode generator runs only while
recording.
Note
Set to FREE RUN when carrying out editing with an editing
control unit. With the REC RUN setting, editing will not be
carried out correctly.
DF MODE [> DF mode]:
Select whether the timecode
generator and time counter operate in drop frame mode or
non-drop frame mode.
Normally select drop frame mode to keep in
synchronization with real time. The non-drop frame mode
is useful for example when using computer graphics, and
working on a frame count basis.
Note
Displayed only when the system frequency is set to 60i.
*
ON (DF) [>> ON (DF)]:
Drop frame mode
OFF (NDF) [>> OFF (NDF)]:
Non-drop frame mode
DISPLAY CONTROL [Display]: Settings related to monitor
display and indicators
Description of settings