1-18
VPL-S900E, VPL-S900M, VPL-S900U
34
(EN)
a
x
b
Ceiling Installation
When installing the projector on the ceiling, use the
PSS-600 Projector Suspension Support.
a: Distance between the screen and the center of lens
b: Distance between the ceiling and the center of the lens
x: Distance between the ceiling and the center of the screen
Center of the lens
Screen size (inches)
80
100
120
150
180
200
250
300
Minimum
3240
4070
4900
6150
7410
8240
10320
12410
a
(127
5
/
8
)
(160
3
/
8
)
(193)
(242
1
/
4
)
(291
7
/
8
)
(324
1
/
2
)
(406
3
/
8
)
(488
3
/
4
)
Maximum
4090
5130
6180
7750
9310
10360
12970
15580
(161
1
/
8
)
(202)
(243
3
/
8
)
(305
1
/
4
)
(366
5
/
8
)
(408)
(510
3
/
4
)
(613
1
/
2
)
x
b+585
b+731
b+877
b+1097
b+1316
b+1462
b+1828
b+2194
(23
1
/
8
)
(28
7
/
8
)
(34
5
/
8
)
(43
1
/
4
)
(51
7
/
8
)
(57
5
/
8
)
(72)
(86
1
/
2
)
b
226/251/276/326/351/376 mm (9/10/10
7
/
8
/12
7
/
8
/13
7
/
8
/14
7
/
8
inches) adjustable when using PSS-600
Wall
PSS-600 Projector Suspension Support
(not supplied)
Ceiling
Unit: mm (inches)
Center of the screen
For ceiling installation, consult with qualified Sony
personnel.
To calculate the installation measurement (unit: mm)
SS: screen size diagonal (inches)
a (minimum) = {(SS
×
52.83/1.2992) – 95.03}
×
1.025
a (maximum) = {(SS
×
69.64/1.2992) – 96.17}
×
0.975
x = b + SS/1.2992
×
9.5
Installation Examples
Distance from the front of
the cabinet and the center
of the lens
40 mm (1
5
/
8
inches)
35
(EN)
Unsuitable Installation
Poorly ventilated
• Allow adequate air circulation to prevent internal heat
build-up. Do not place the unit on surfaces (rugs,
blankets, etc.) or near materials (curtains, draperies) that
may block the ventilation holes. When the internal heat
builds up due to the block-up, the temperature sensor will
function with the message “High Temperature! Power off
in 1 min.” The power will be turned off automatically
after one minute.
• Leave space of more than 30 cm (11
7
/
8
inches) around
the front ventilation holes.
• Be careful that the bottom ventilation holes may inhale
tininess such as a piece of paper.
• If you put something in front of the front ventilation
holes, the exhaust may be inhaled into the projector
through the ventilation holes at the bottom, causing the
internal temperature to rise, which activates the
protection circuit. Install the projector so that the exhaust
is not blocked.
Highly heated and humid
• Avoid installing the unit in a location where the
temperature or humidity is very high, or temperature is
very low.
• To avoid moisture condensation, do not install the unit in
a location where the temperature may rise rapidly.
Very dusty
Avoid installing the unit in a location where there is a lot of
dust; otherwise, the air filter will be obstructed. The dust
blocking the air through the filter may cause raising the
internal heat of the projector. Clean it up periodically.
Do not install the projector in the following situations. These installations
may cause mulfunction or damage to the projector.
Summary of Contents for IFB-X600E
Page 5: ...5 VPL S900E VPL S900M VPL S900U F Board 8 24 GA Board 8 24 GB Board 8 26 GBA Board 8 28 ...
Page 6: ......
Page 47: ...1 41 VPL S900E VPL S900M VPL S900U ...
Page 48: ...1 42 VPL S900E VPL S900M VPL S900U ...
Page 49: ...1 43 VPL S900E VPL S900M VPL S900U ...
Page 50: ...1 44 VPL S900E VPL S900M VPL S900U ...
Page 51: ...1 45 VPL S900E VPL S900M VPL S900U ...
Page 52: ...1 46 VPL S900E VPL S900M VPL S900U ...
Page 53: ...1 47 VPL S900E VPL S900M VPL S900U ...
Page 54: ...1 48 VPL S900E VPL S900M VPL S900U ...
Page 55: ...1 49 VPL S900E VPL S900M VPL S900U ...
Page 56: ......
Page 62: ......
Page 70: ......
Page 78: ......
Page 144: ......