Specifications
15
Troubleshooting
Before contacting your retailer or a Sony Support
Center, please check the following items. If the problem
persists, contact them.
The unit does not work.
• Verify that the power switch is turned on.
• Verify that the power cable is connected correctly.
• Make sure the wall outlet has power. Test it by
plugging another device.
• Verify that the hard disk drives are not being accessed
(the HDD LEDs on the front of the recorder do not
blink), and then turn it off forcibly by pressing and
holding the power switch at the rear of the unit for
approximately 10 seconds. Restart the unit.
• During the startup procedure, the unit checks the file
system. The length of this check varies depending on
the amount of data on the unit (in some extreme case,
it can take as long as two hours). During the file
system check, the HDD LEDs on the front of the
recorder blink.
Cannot access the hard disk drive.
• Make sure the hard disk drive is properly inserted.
• Check the HDD LEDs on the front panel of the
system. Identify the defective hard disk drive by
reading the drive LEDs. A defective HDD LED lights
umber.
• Due to rapid flashing during frequent access to the
hard disk drive, the HDD LED may appear unlit in
bright environments.
The unit heats up quickly
• Make sure that nothing is blocking the ventilation
openings on the front, sides, and rear of the unit and
dust has not accumulated in them.
Specifications
NSRE-S200
Recording devices
Internal hard disk drive
2 TB (SATA-II 500 GB
×
4)
Capacities for hard disk drives are based
on the following equation for 1 GB:
1,000
×
1,000
×
1,000 = 1 billion bytes
External connectors
Rear
Mini-SAS input (for NSR-1000 series /
NSRE-S200 connection, mini-SAS
(SFF-8088), 3.0 Gbit/s) (1)
Mini-SAS output (for NSRE-S200
connection, mini-SAS (SFF-8088),
3.0 Gbit/s) (2)
Maintenance serial connector: RS-232C (1)
Maintenance LAN connector
(100Base-TX/10Base-T) (RJ-45) (1)
Operating environment
Operating temperature
5 °C to 40 °C (41 °F to 104 °F)
Operating humidity
20% to 80% (maximum wet-bulb
temperature: 30 °C, noncondensing)
Temperature range for storage
–20 °C to +60 °C (–4 °F to +140 °F)
Humidity range for storage
20% to 90% relative humidity (maximum
wet-bulb temperature 35 °C/95 °F, no
condensation)
Power and miscellaneous
Power
100 to 127 V AC/200 to 240 V AC
(50/60 Hz)
Power consumption
Max. 350 W
Dimensions
430
×
87
×
417 mm (16.9
×
3.4
×
16.4 in.)
(W/H/D, excluding protrusions)
Mass
approx. 12 kg (26.7 lb.)
Optional accessories
NSR-RM1 Rack Mounting Kit
Design and specifications are subject to change without
notice.
Notes
•
Always make a test recording, and verify that it was
recorded successfully.
SONY WILL NOT BE LIABLE FOR DAMAGES OF
ANY KIND INCLUDING, BUT NOT LIMITED TO,
COMPENSATION OR REIMBURSEMENT ON
ACCOUNT OF FAILURE OF THIS UNIT OR ITS
RECORDING MEDIA, EXTERNAL STORAGE
SYSTEMS OR ANY OTHER MEDIA OR STORAGE
SYSTEMS TO RECORD CONTENT OF ANY TYPE.
•
Always verify that the unit is operating properly before use.
SONY WILL NOT BE LIABLE FOR DAMAGES OF
ANY KIND INCLUDING, BUT NOT LIMITED TO,
COMPENSATION OR REIMBURSEMENT ON
ACCOUNT OF THE LOSS OF PRESENT OR
PROSPECTIVE PROFITS DUE TO FAILURE OF THIS
UNIT, EITHER DURING THE WARRANTY PERIOD OR
AFTER EXPIRATION OF THE WARRANTY, OR FOR
ANY OTHER REASON WHATSOEVER.