Sending an Image via E-mail — e-Mail (SMTP) Menu
66
Alarm sending Tab — Setting the
e-mail sending mode when
detecting the alarm
Set to send an e-mail linked with alarm detection by the
external sensor input or by the built-in detection
functions.
Note
When more than two of the following settings are
activated, the camera only creates two still images at the
same time. A third still image cannot be created unless
one of the previous two still images is sent.
e-Mail (SMTP) menu
– Alarm sending tab
Alarm sending
(when file
attachment is set to On).
– Periodical sending
Periodical sending
FTP client menu
– Alarm sending tab
Alarm sending
– Periodical sending
Periodical sending
Trigger menu
–
Mail (SMTP)
– FTP Client
Alarm sending
Select
On
to set sending an e-mail linked with alarm
detection.
File attachment
Set whether an image file (JPEG file) is to be attached to
the e-mail or not.
When
On
is selected, the image file made using the
settings below is attached. When
Off
is selected, only
the message is sent.
Image file name
Type the file name you want to assign to the image to be
attached to an e-mail. You can use up to 10
alphanumeric characters, – (hyphen) and _ (underscore)
for naming.
Suffix
Select a suffix to be added to the file name.
None:
No suffix is added. The image file name is
assigned to the image to be sent via e-mail.
Date & time:
The date & time suffix is added to the
image file name.
The date/time suffix consists of lower two-digits of
the year (2 digits), month (2 digits), date (2 digits),
hour (2 digits), minute (2 digits), second (2 digits),
and sequential number (2 digits), thus adding 14-
digit number to the image file name.
Sequence number:
A sequential number of 10 digits
between 0000000001 and 4294967295 and two fixed
digits 00 are added to the image file name.
Sequence number clear
Click
Clear
to reset the
Sequence number
suffix to 1.
Alarm
Select the alarm to be linked with e-mail notification.
Sensor input 1:
The external sensor that is connected to
sensor input of the camera I/O port.
Camera tampering detection:
An alarm that is
triggered when the camera detects tampering such as
direction shifting or spray.
Interval:
Set the interval at which you want to send an
e-mail periodically after detection.
E-mails are sent after a specified interval, until the
Camera tampering detection setting is cleared or the
detection setting is turned off. You can set the hour
(H) and minutes (M) between 30 minutes and
24 hours (one day).
When file attachment is set to ON, a file is only
attached to an initial mail and will not be attached to
the following mails.
Motion detection:
The alarm is detected by the motion
detection function.
Click
Detection
, and the motion detection menu is
displayed to allow you to set the motion detection
function (page 73).