6
KDL-40NX705/46NX705
KDL-40NX705/46NX705
SECTION 1: DIAGRAMS
1-1. CIRCUIT BOARDS LOCATION
1-2. PRINTED WIRING BOARDS AND SCHEMATIC DIAGRAMS INFORMATION
All voltages are in V.
S : Measurement impossibility.
: B+line.
: B-line. (Actual measured value may be different).
: signal path. (RF)
Circled numbers are waveform references.
The components identi
fi
ed by shading and
!
symbol are critical for safety. Replace
only with part number speci
fi
ed.
The symbol
indicates a fast operating fuse and is displayed on the component
side of the board. Replace only with fuse of the same rating as marked.
NOTE: The components identi
fi
ed by a red outline and a mark contain con
fi
dential
information. Speci
fi
c instructions must be adhered to whenever these components
are repaired and/or replaced.
See Appendix A: Encryption Key Components in the back of this manual.
All capacitors are in
μ
F unless otherwise noted. pF :
μμ
F 50WV or
less are not indicated except for electrolytics and tantalums.
All electrolytics are in 50V unless otherwise speci
fi
ed.
All resistors are in ohms. k
=1000
, M
=1000k
Indication of resistance, which does not have one for rating
electrical power, is as follows:
Pitch : 5mm
Rating
electrical
power
:
1
/
4
W
1
/
4
W in resistance,
1
/
10
W and
1
/
16
W in chip resistance.
: non
fl
ammable resistor
: fusible resistor
: internal component
: panel designation and adjustment for repair
: earth ground
: earth-chassis
All variable and adjustable resistors have characteristic curve B,
unless otherwise noted.
Readings are taken with a color-bar signal input.
Readings are taken with a 10M
digital multimeter.
Voltages are DC with respect to ground unless otherwise noted.
Voltage variations may be noted due to normal production
tolerances.
GE3A (KDL-40NX705 ONLY)
GE2B (KDL-46NX705 ONLY)
WIRELESS
LAN CARD
SWITCH UNIT
HLR
BUHS