37
2
Manually adjust the projectors.
To ensure proper calibration, be sure to manually
adjust the projection area size, center position, and
brightness of each projector so that they
approximately match before using the calibration
camera’s application. (Such adjustments are
ordinarily performed during installation.)
If the positions of the two projectors’ screens are not
sufficiently aligned beforehand, calibration via the
calibration camera’s application may result in error.
Caution
This step is not required ordinarily, as manual
adjustment is performed during initial installation.
However, if the positions of the projectors have
shifted significantly since installation, readjustment is
required.
3
Ingest the DCP for adjustment, and play back the
CPL.
The calibration camera’s application must be
performed with the same alignment CPL being played
back from both projectors.
Select CPLs for which the mask configurations for the
target screen and projector function settings match,
and manually adjust the screen with the CPL in a
paused state.
Caution
For details on the alignment DCP, contact qualified
Sony service personnel.
4
Check the ambient light.
Make sure the area around the screen is as similar as
possible to the actual screening conditions.
Spotlights or other bright lights near the screen may
result in calibration errors.
Performing Calibration
Touch sensor notation
In this manual, touch sensor functions are indicated as
follows.
FX [XXXXXX]
FX:
Indicates the corresponding touch sensor button (F1,
F2, or F3).
[XXXXXX]:
Indicates the function name.
Caution
Do not operate the server via touch panel monitor or
browser operations while using the calibration camera. If
such operations are performed, the calibration camera’s
functions may not operate properly. If a function does not
operate properly, return to the main menu and start the
procedure over from the beginning.
1
Tap [ALIGNMENT] while the main menu is
displayed, and then tap F3 [ENTER].
2
Tap [CALIBRATION], and then tap F3 [EXEC].
The calibration sequence will start according to the
mode and settings configured in [OPTION] -
[CALIBRATION MODE] and [OPTION] - [PJT
THROW RATIO]. Be sure to configure the
[OPTION] - [CALIBRATION MODE] and
[OPTION] - [PJT THROW RATIO] settings
beforehand.
[OPTION] - [CALIBRATION MODE]
[STATIC]:
Corrects distortions in the sub projector’s
projected image using the main projector’s image
as a reference, superimposing both images. As
adjustments based on previous calibration
values, calibration times will be shorter with
smaller shifts in the projected images. Use this
setting under normal circumstances.
[TRACE]:
Corrects distortions in the sub projector’s
projected image using the main projector’s image
as a reference, overlaying both images on each
other. The main projector will only be adjusted if
calibration on the sub projector alone is
insufficient. As adjustments based on previous
calibration values, calibration times will be
P C A B
U T I L I T Y
S E L E C T E N T E R
A L I G N M E N T
P C A B > A L I G N M E N T
T E S T P A T T E R N
C A L I B R A T I O N
Z E R O - R E S E T
O P T I O N
R E T U R N S E L E C T E X E C
Summary of Contents for LKRA-010