– 18 –
10.
Auto White Balance & LV Reference Data Acquisition
Note 1:
Color Reproduction Adjustment must be already finished.
Note 2:
The auto white balance & LV reference data acquisition is available only once after the power is turned on. Turn the power off,
then on again if the data acquisition is retried.
Note 3:
For the data display, the data at the time when address was set is displayed, and it is not updated.
Check data variation while repeating address change and resetting (change address from “02” to “01”, and then return it to “02”).
Adjusting method
Steps
Page
Address
Data
Work Description
1
06
02
Check that the data is “00”.
2
06
01
11
Press the
y
key.
3
06
01
0D
Press the
y
key.
(The auto white balance & LV reference data acquisition is carried out, and the data are
automatically entered to page: F, address: 20 – 23, 3E, 3F.)
4
06
02
Check that the data becomes “01”. (Note 3)
Processing after completion of adjustment
Steps
Page
Address
Data
Work Description
1
06
01
00
Press the
y
key.
2
Perform “Auto White Balance Adjustment”.
11.
Auto White Balance Adjustment
Adjust auto white balance so that correct data are outputted.
If deviated, color reproduction in the auto white balance mode will be reduced.
Note 1:
“Auto White Balance & LV Reference Data Acquisition” must be already finished.
Note 2:
The auto white balance adjustment is available only once after the power is turned on. Turn the power off, then on again if the
adjustment is retried.
Note 3:
For the data display, the data at the time when address was set is displayed, and it is not updated.
Check data variation while repeating address change and resetting (change address from “02” to “01”, and then return it to “02”).
Adjusting method
Steps
Page
Address
Data
Work Description
1
Cover the lens with the color temperature correction filter C14.
2
06
02
Check that the data is “00”.
3
06
01
83
Press the
y
key.
4
06
01
81
Press the
y
key.
(The auto white balance adjustment is carried out, and the data are automatically entered
to page: F, address: 34, 35.)
5
06
02
Check that the data becomes “01”. (Note 3)
Processing after completion of adjustment
Steps
Page
Address
Data
Work Description
1
06
01
00
Press the
y
key.
Subject
Clear chart (PTB-450)
(Color reproduction adjusting frame)
Adjustment page
0F
Adjustment address
20 – 23, 3E, 3F
Subject
Clear chart (PTB-450)
(Color reproduction adjusting frame)
Filter
Color temperature correction filter C14
Measurement point
Displayed data on page: 01
Adjustment page
0F
Adjustment address
34, 35
Summary of Contents for MDDISCAM DCM-M1
Page 5: ...1 1 SECTION 1 GENERAL This section is extracted from in struction manual 3 866 152 11 DCM M1 ...
Page 6: ...1 2 ...
Page 7: ...1 3 ...
Page 8: ...1 4 ...
Page 9: ...1 5 ...
Page 10: ...1 6 ...
Page 11: ...1 7 ...
Page 12: ...1 8 ...
Page 13: ...1 9 ...
Page 14: ...1 10 ...
Page 15: ...1 11 ...
Page 16: ...1 12 ...
Page 17: ...1 13 ...
Page 18: ...1 14 ...
Page 19: ...1 15 ...
Page 20: ...1 16 ...
Page 21: ...1 17 ...
Page 22: ...1 18 ...
Page 23: ...1 19 ...
Page 24: ...1 20 ...
Page 25: ...1 21 ...
Page 26: ...1 22 ...
Page 27: ...1 23 ...
Page 28: ...1 24 ...
Page 29: ...1 25 ...
Page 30: ...1 26 ...
Page 31: ...1 27 ...
Page 32: ...1 28 ...
Page 33: ...1 29 ...
Page 34: ...1 30 1 30 E ...
Page 47: ...2 13 MEMO ...
Page 69: ...DCM M1 4 5 4 6 4 7 4 8 4 1 FRAME SCHEMATIC DIAGRAM FRAME ...
Page 96: ...DCM M1 4 115 4 113 4 114 ETHER INTERFACE ETHER ...