24
9. Press the YES button display “EFB =
MO-P”.
Then, the optical pick-up moves to the pit area automatically
and servo is imposed.
10. Observe the waveform of the oscilloscope, and check that the
specified value is satisfied. Do not rotate the AMS knob.
(Traverse Waveform)
Checking Procedure:
1. Connect an oscilloscope to CN105 pin
4
(TE) and CN105 pin
6
(VC) of the BD board.
2. Load a test disc (MDW-74/GA-1). (Refer to Note 1.)
3. Press the
M
button and move the optical pick-up outside the
pit.
4. Rotate the AMS knob and display “EF MO CHECK”.
5. Press the YES button and display “EFB =
MO-R”.
(Laser power READ power/Focus servo ON/tracking servo OFF/
spindle (S) servo ON)
V : 0.5 V/div
H : 10 ms/div
Input : DC mode
Oscilloscope
BD board
CN105 pin
4
(TE)
CN105 pin
6
(VC)
VC
A
B
Specified value : Below 10% offset value
Offset value (%) = X 100
IA – BI
2 (A + B)
VC
A
B
Specified value : Below 10% offset value
Offset value (%) = X 100
IA – BI
2 (A + B)
5-6-4. Auto Check
This test mode performs C-REC and C-PLAY automatically for
mainly checking the characteristics of the optical pick-up. To
perform this test mode, the laser power must first be checked.
Perform Auto Check after the laser power check and Iop compare.
Procedure
1. Press the YES button. If “LDPWR minicheck” is displayed, it
means that the laser power check has not been performed. In
this case, perform the laser power check and Iop compare, and
then repeat from step 1.
2. If a disc is in the mechanical deck, it will be ejected forcibly.
“DISC IN” will be displayed in this case. Load a test disc (MDW-
74/GA-1) which can be recorded.
3. If a disk is loaded at step 2, the check will start automatically.
4. When “XX CHECK” is displayed, the item corresponding to
XX will be performed.
When “06 CHECK” completes, the disc loaded at step 2 will be
ejected. “DISC IN” will be displayed. Load the check disc (MD)
TDYS-1.
5. When the disc is loaded, the check will automatically be resumed
from “07 CHECK”.
6. After completing to test item 12, check OK or NG will be
displayed. If all items are OK, “CHECK ALL OK” will be
displayed. If any item is NG, it will be displayed as “NG:xxxx”.
When “CHECK ALL OK” is displayed, it means that the optical
pick-up is normal. Check the operations of the other spindle motor,
thread motor, etc.
When displayed as “NG:xxxx”, it means that the optical pick-up is
faulty. In this case, replace the optical pick-up.
5-6-5. Other Checks
All the following checks are performed by the Auto Check mode.
They therefore need not be performed in normal operation.
1. Load a continuously recorded test disc (MDW-74/GA-1).
(Refer to “5-5. Using the Continuously Recorded Disc”.)
5-6-6. Traverse Check
Connection :
VC
A
B
Specified value : Below 10% offset value
Offset value (%) = X 100
IA – BI
2 (A + B)
7. Press the YES button and display “EFB =
MO-W”.
8. Observe the waveform of the oscilloscope, and check that the
specified value is satisfied. Do not rotate the AMS knob.
(Write power traverse checking)
(Traverse Waveform)
6. Observe the waveform of the oscilloscope, and check that the
specified value is satisfied. Do not rotate the AMS knob.
(Read power traverse checking)
(Traverse Waveform)
11. Press the YES button display “EF MO CHECK”
The disc stops rotating automatically.
12. Press the
A
button and remove the disc.
13. Load the check disc (MD) TDYS-1.
14. Roteto the AMS knob and display “EF CD CHECK” (C04).
15. Press the YES button and display “EFB =
CD”. Servo is
imposed automatically.
Summary of Contents for MDS-JE440 - Md Player
Page 42: ...MDS JE440 42 42 6 10 SCHEMATIC DIAGRAM MAIN SECTION 3 3 See page 47 for IC Block Diagrams ...
Page 43: ...MDS JE440 43 43 6 11 PRINTED WIRING BOARD POWER SECTION ...
Page 44: ...MDS JE440 44 44 6 12 PRINTED WIRING BOARD DISPLAY SECTION ...
Page 45: ...MDS JE440 45 45 6 13 SCHEMATIC DIAGRAM DISPLAY SECTION See page 34 for Waveforms ...