29
MDS-S9
5-15. ERROR RATE CHECK
5-15-1. CD Error Rate Check
Procedure:
1. Load the check disc (TDYS-1).
2. Turn the
[ AMS ]
knob to display “CPLAY1MODE”
(C34).
3. Press the
[YES]
button twice and display “CPLAY1MID”.
4. The display changes to “C =
AD =
)”.
5. Check that the C1 error rate is below 20.
6. Press the
[MENU/NO]
button to stop playback, then press
the
Z
button and take out the check disc (TDYS-1).
5-15-2. MO Error Rate Check
Procedure:
1. Load the continuously-recorded disc. (Refer to “5-6. USING
THE CONTINUOUSLY RECORDED DISC” (See page 23))
2. Turn the
[ AMS ]
knob to display “CPLAY1MODE”
(C34).
3. Press the
[YES]
button to display “CPLAY1MID”.
4. The display changes to “C =
AD =
)”.
5. If the C1 error rate is below 20, check that ADER is 00.
6. Press the
[MENU/NO]
button to stop playback, then press
the
Z
button and take out the disc.
5-16. FOCUS BIAS CHECK
Change the focus bias and check the focus tolerance amount.
Procedure:
1. Load the continuously-recorded disc. (Refer to “5-6. USING
THE CONTINUOUSLY RECORDED DISC” (See page 23))
2. Turn the
[ AMS ]
knob to display “CPLAY1MODE”
(C34).
3. Press the
[YES]
button twice to display “CPLAY1MID”.
4. Press the
[MENU/NO]
button when “C =
AD =
)” is
displayed.
5. Turn the
[ AMS ]
knob to display “FBIAS CHECK”
(C16).
6. Press the
[YES]
button to display “
/
c =
T”.
The first four digits indicate the C1 error rate, the two digits
after “/ ” indicate ADER, and the 2 digits after “c =” indicate
the focus bias value.
Check that the C1 error is below 20 and ADER is below 2.
7. Press the
[YES]
button and display “
/
b =
T”.
Check that the C1 error is below 100 and ADER is below 2.
8. Press the
[YES]
button and display “
/
a =
T”.
Check that the C1 error is below 100 and ADER is below 2
9. Press the
[MENU/NO]
button, then press the
Z
button and
take out the disc.
Note:
If the C1 error and ADER are above other than the specified
value at points a (step 8. in the above) or b (step 7. in the above),
the focus bias adjustment may not have been carried out prop-
erly. Adjust perform the beginning again.
5-17. AUTO GAIN CONTROL OUTPUT LEVEL
ADJUSTMENT
Be sure to perform this adjustment when the optical pick-up is
replaced.
If the adjustment results becomes “Adjust NG!”, the optical pick-
up may be faulty or the servo system circuits may be abnormal.
5-17-1. CD Auto Gain Control Output Level Adjustment
Procedure:
1. Load the check disc (TDYS-1).
2. Turn the
[ AMS ]
knob to display “AG Set (CD)” (C11).
3. When the
[YES]
button is pressed, the adjustment will be per-
formed automatically.
“Complete!!” will then be displayed momentarily when the
value is recorded in the non-volatile memory, after which the
display changes to “AG Set (CD)” (C11).
4. Press the
Z
button and take out the check disc (TDYS-1).
5-17-2. MO Auto Gain Control Output Level Adjustment
Procedure:
1. Load the test disc (MDW-74/GA-1).
2. Turn the
[ AMS ]
knob to display “AG Set (MO)” (C10).
3. When the
[YES]
button is pressed, the adjustment will be per-
formed automatically.
“Complete!!” will then be displayed momentarily when the
value is recorded in the non-volatile memory, after which the
display changes to “AG Set (MO)” (C10).
4. Press the
Z
button and take out the test disc
(MDW-74/GA-1).
. >
. >
. >
. >
. >
. >