8
MDS-S9
RETRY CAUSE DISPLAY MODE IN MD
• In this test mode, the causes for retry of the unit during recording and stop can be displayed on the liquid crystal display. During
playback, the “track mode” for obtaining track information will be set.
This is useful for locating the faulty part of the unit.
• The following will be displayed :
During recording and stop : Retry cause, number of retries, and number of retry errors.
During playback
: Information such as type of disc played, part played, copyright.
These are displayed in hexadecimal.
Precedure:
1. Keep the
x
button pressed for about 10 seconds, or press the
[LEVER/DISPLAY/CHAR]
button while pressing
x
and
[MENU/NO]
buttons.
2. “RTs00c00e000” is displayed after the mode is set.
3. Press the
z
button go into recording mode, then press the
u
button to start recording.
4. To check “track mode”, press the
u
button to playback.
5. To release the test mode, press the
I/
1
button and turn off the power. Remove the power plug from the outlet after “TOC” is turned
off. If you cannot release the test mode, refer to “FORCE RESET” on page 7.
Fig. 1 Reading the Test Mode Display
(During recording and stop)
RTs@@c##e
***
Liquid crystal display
@@ : Cause of retry
##
: Number of retries
***
: Number of retry errors
Fig. 2 Reading the Test Mode Display
(During playback)
@@ ###
**
$$
Liquid crystal display
@@ : Parts No. (Name of area named on TOC)
### : Cluster
Address (Physical address on the
**
: Sector
disc)
$$
: Track mode (Track information such as copy-
right information of each part)
Reading the Retry Cause Display
8
4
2
1
8
4
2
1
b7 b6 b5 b4 b3 b2 b1 b0
0
0
0
0
0
0
0
1
0
0
0
0
0
0
1
0
0
0
0
0
0
1
0
0
0
0
0
0
1
0
0
0
0
0
0
1
0
0
0
0
0
0
1
0
0
0
0
0
0
1
0
0
0
0
0
0
1
0
0
0
0
0
0
0
Hexa-
decimal
Cause of Retry
01
02
04
08
10
20
40
80
Higher Bits
Lower Bits
Hexadecimal
Bit
Binary
shock
ader5
Discontinuous address
DIN unlock
FCS incorrect
IVR rec error
CLV unlock
Access fault
Occurring conditions
When track jump (shock) is detected
When ADER was counted more than five times
continuously
When ADIP address is not continuous
When DIN unlock is detected
When not in focus
When ABCD signal level exceeds the specified range
When CLV is unlocked
When access operation is not performed normally
Reading the Display:
Convert the hexadecimal display into binary display. If more than two causes, they will be added.
Example
When 42 is displayed:
Higher bit : 4 = 0100
t
b6
Lower bit : 2 = 0010
t
b1
In this case, the retry cause is combined of “CLV unlock” and “ader5”.
When A2 is displayed:
Higher bit : A = 1010
t
b7 + b5
Lower bit : 2 = 0010
t
b1
The retry cause in this case is combined of “Access fault”, “IVR rec error”, and “ader5”.