Advanced Key Operations
Note
Pressing a button which is lit in orange or yellow will
overwrite the current contents of the register.
When the save is complete, the button that you pressed
lights in yellow and the number on the button changes
from a register number to an effect pattern figure.
The pattern number appears in the numeric display.
Recalling effect snapshots
1
In the Flexi Pad control block, press the [EFF/WIPE]
button, lighting it.
2
If the [STORE] button is lit, press it to turn it off.
3
Press to light the region selection button (M/E or PP/
ALL) for the region of the snapshot that you want to
recall.
The memory recall buttons show figures of the saved
effect patterns. Buttons where snapshots are already
saved are lit in orange.
4
Press the memory recall button for the effect snapshot
that you want.
When the recall finishes, the pressed button lights in
yellow and the numeric display shows the pattern
number of the corresponding pattern.
Deleting effect snapshots
With the [STORE] button lit, hold the [EFF/WIPE] button
down and press the memory recall button for the effect
snapshot that you want to delete. The button you pressed is
turned off, and the effect snapshot is deleted.
Advanced Key
Operations
This section explains procedures for setting M/E key 1.
The same procedures can be used for the other keys as well
(M/E key 2, and downstream keys 1 and 2).
Processing Key Signals
To turn key clean mode on
Clean mode
In a luminance key or linear key, you can enable the clean
mode. When the clean mode is on, the key source does not
affect the key fill, which is added unchanged to the
background. This improves the keyed image quality, but
means that the part of the key fill signal which is not to be
inserted must be completely black, or it will color the
background.
This mode is effective when using character generators,
which generate paired key source and key fill signals.
Note that in the following situations, the clean mode goes
off, and cannot be turned on.
• When the key type is a pattern key or chroma key
• When key inversion (Key Invert) is on
• When the Key Position function is on
• When fine key is on
• When the key fill is a matte
• When the key edge is anything other than normal
• When the key edge is normal, and soft edges are on
To turn clean mode on
1
From the top menu, select Key >M/E Key1 >Key
Source.
The Key Source menu appears.
2
Press [Clean Mode], turning it on.
4
1
2
3
EFF/
WIPE
SNAP
SHOT
PP/
ALL
BANK
SEL
TRANS
RATE
M/E
MCRO
STORE
7
8
9
4
5
6
1
2
3
10
ENTR
PTN
NO.