— 33 —
5-7. TRAVERSE ADJUSTMENT
Connection :
Oscilloscope
V : 0.5 V/div
H : 10 ms/div
Input : DC mode
BD board
CN110 pin
3
(TEO)
CN110 pin
2
(VC)
Adjusting method :
1. Connect an oscilloscope to CN110 pin
3
(TEO) and CN110
pin
2
(VC) of the BD board.
2. Load a disc (any available on the market). (Refer to Note 1.)
3. Press the
0
button or
)
button and move the optical pick-
up outside the pit.
4. Rotate the AMS knob and display “EFBAL ADJUST”.
5. Press the YES button and display “EFB =
MO-R”.
(Laser power READ power/Focus servo ON/tracking servo OFF/
spindle (S) servo ON)
6. Rotate the AMS knob so that the waveform of the oscilloscope
becomes the specified value.
(When the AMS knob is rotated, the
of “EFB=
” changes
and the waveform changes.) In this adjustment, waveform var-
ies at intervals of approx. 2%. Adjust the waveform so that the
specified value is satisfied as much as possible.
(Read power traverse adjustment)
(Traverse Waveform)
VC
A
B
Specification A = B
7. Press the YES button and save the result of adjustment to the
non-volatile memory (“EFB =
SAVE” will be displayed for a
moment. Then “EFB =
MO-W” will be displayed).
8. Rotate the AMS knob so that the waveform of the oscilloscope
becomes the specified value.
(When the AMS knob is rotated, the
of “EFB-
” changes
and the waveform changes.) In this adjustment, waveform var-
ies at intervals of approx. 2%. Adjust the waveform so that the
specified value is satisfied as much as possible.
(Write power traverse adjustment)
(Traverse Waveform)
VC
A
Specification A = B
B
9. Press the YES button, and save the adjustment results in the non-
volatile memory. (“EFB =
SAVE” will be displayed for a
moment.)
10. “EFB =
MO-P”. will be displayed.
The optical pick-up moves to the pit area automatically and servo
is imposed.
11. Rotate the AMS knob until the waveform of the oscilloscope
moves closer to the specified value.
In this adjustment, waveform varies at intervals of approx. 2%.
Adjust the waveform so that the specified value is satisfied as
much as possible.
(Traverse Waveform)
VC
A
B
Specification A = B
12. Press the YES button, and save the adjustment results in the
non-volatile memory. (“EFB =
SAVE” will be displayed for
a moment.)
Next “EFBAL CD” is displayed. The disc stops rotating auto-
matically.
13. Press the
§
button and remove the disc.
14. Load the check disc (MD) TDYS-1.
15. Press the YES button and display “EFB =
CD”. Servo is
imposed automatically.
16. Rotate the AMS knob so that the waveform of the oscilloscope
moves closer to the specified value.
In this adjustment, waveform varies at intervals of approx. 2%.
Adjust the waveform so that the specified value is satisfied as
much as possible.
(Traverse Waveform)
VC
A
B
Specification A = B
17. Press the YES button, display “EFB =
SAVE” for a moment
and save the adjustment results in the non-volatile memory.
Next “EFBAL ADJUST” will be displayed.
18. Press the
§
button and remove the check disc (MD) TDYS-1.
Note 1 : MO reading data will be erased during if a recorded disc is
used in this adjustment.
Note 2 : If the traverse waveform is not clear, connect the oscillo-
scope as shown in the following figure so that it can be
seen more clearly.
Oscilloscope
330 k
Ω
10pF
BD board
CN110 pin
3
(TEO)
CN110 pin
2
(VC)
Summary of Contents for MINIDISC DECK MDS-S38
Page 8: ... 8 This section is extracted from instruction manual ...
Page 9: ... 9 ...
Page 10: ... 10 ...
Page 11: ... 11 ...
Page 12: ... 12 ...
Page 13: ... 13 ...
Page 14: ... 14 ...
Page 15: ... 15 ...
Page 16: ... 16 ...
Page 17: ... 17 ...
Page 18: ... 18 ...
Page 19: ... 19 ...
Page 20: ... 20 ...
Page 21: ... 21 ...
Page 26: ... 26 3 7 OVER WRITE HEAD 1 Precision screw P1 7x6 2 Over write head ...
Page 38: ......
Page 39: ......
Page 40: ......
Page 41: ......
Page 42: ......
Page 43: ......
Page 44: ......
Page 67: ...MDS S38 MEMO 85 ...