background image

15

Specifications

Specifications

The following specifications show the reference 
performance for this unit and individual option boards.

Design and specifications are subject to change without 
notice.

MVE-8000A Multi Format DME 
Processor

General

Power requirements

100 to 240 V AC, 50/60 Hz

Power consumption

2.8 to 1.2 A

Peak inrush current

(1) Power ON, current probe method: 

15 A (100 V), 66 A (240 V)

(2) Hot switching inrush current, 

measured in accordance with 
European standard EN55103-1: 50 A 
(230 V)

Performance temperature

5ºC to 40ºC (41ºF to 104ºF)

Operating temperature

10ºC to 35ºC (50ºF to 95ºF)

Storage temperature

20ºC to +60ºC (

4ºF to 

+

140ºF)

Operating humidity

10% to 90%

Dimensions (w/h/d, excluding projections)

440×87.5×520 mm 

(17 

3

/

× 3 

1

/

× 20 

1

/

2

 inches)

Mass

Approx. 16 kg (35 lb 4 oz)

(when equipped with all installable 
option boards)

Reference input

REF IN

BNC type, 75

 with loop-through output

HDTV systems: HD tri-level sync/SDTV 

analog black burst/SDTV analog sync

SDTV systems: Analog black burst/

analog sync

Control connectors

CTRL

RJ-45
Complies with 100 Base-TX standard

DATA

RJ-45
Complies with 100 Base-TX standard

REMOTE 1 to 4

D-sub 9-pin, female
Complies with RS-422A standard
Data transfer rate: 38.4 Kbps

GPI, GPI2

D-sub 25-pin, female
TTL inputs: 8
Relay contact outputs: 4 

(30 V AC/DC, 0.1 A)

Open collector outputs: 4

AC input

AC IN A, B

3-pin AC connector

System Delay

1 frame

(in other than 720p format)

2 frames

(in 720p format)

Accessories supplied

75

 terminator (1)

Operation Manual (1)
Installation Manual (1)

Accessories not supplied

AC power cord (for USA and Canada only) (125 V 10 A 

2.4 m (8 ft)) (Part No.: 1-557-377-11)

AC power cord (for Europe only) (250 V 10 A 2.4 m 

(8 ft)) (Part No.: 1-782-929-22)

MKE-8020A MVS Interface Board

General

Dimensions (w/d)

278×94 mm 

(11×3 

3

/

4

 inches)

Mass

Approx. 1 kg (2 lb 3 oz)

Video signal inputs and outputs

SWITCHER A, SWITCHER B

Connectors

MDR 68-pin

Signal format

LVDS (special format)

Summary of Contents for MVE-8000A

Page 1: ...DME PROCESSOR PACK MVE 8000A C OPERATION MANUAL English 1st Edition Revised 1 MKE 8020A MKE 8021A MKE 8040A HK PSU02 MULTI FORMAT DME PROCESSOR MVE 8000A ...

Page 2: ...servicing to qualified service personnel WARNING THIS WARNING IS APPLICABLE FOR OTHER COUNTRIES 1 Use the approved Power Cord 3 core mains lead Appliance Connector Plug with earthing contacts that conforms to the safety regulations of each country if applicable 2 Use the Power Cord 3 core mains lead Appliance Connector Plug conforming to the proper ratings Voltage Ampere If you have questions on t...

Page 3: ... Emission EN55103 2 Electromagnetic Susceptibility Immunity This product is intended for use in the following Electromagnetic Environment E4 controlled EMC environment ex TV studio Für Kunden in Europa nur MVE 8000A Dieses Produkt besitzt die CE Kennzeichnung und erfüllt die EMV Richtlinie 89 336 EWG sowie die Niederspannungsrichtlinie 73 23 EWG der EG Kommission Angewandte Normen EN60950 Sicherhe...

Page 4: ...ité aux normes européennes suivantes EN55103 1 Interférences électromagnétiques émission EN55103 2 Sensibilité électromagnétique immunité Ce produit est prévu pour être utilisé dans l environnement électromagnétique suivant E4 environnement EMC contrôlé ex studio de télévision Periodic inspections To guarantee safe long term operation periodic inspections are recommended Please contact your Sony r...

Page 5: ...alled 10 MVS 8000 8000A System Configuration 10 Flow of Video Signals 11 Example System Configuration MKE 8021A Installed 12 MVS 8000 8000A System Configuration 12 Flow of Video Signals 13 Power Supply Unit Status Indicator 14 Specifications 15 MVE 8000A Multi Format DME Processor 15 MKE 8020A MVS Interface Board 15 MKE 8021A Input Output Board 16 MKE 8040A Effects Board 16 HK PSU02 Power Supply U...

Page 6: ... internal channels up to 4 channel effects can be applied without making any special connections Linked operation with switcher processor This unit is connected to the MVS 8000 8000A Multi Format Switcher Processor by a special interface which allows DME wipes processed keys and a wide variety of other DME effects to be used as if they were switcher functions All DME operations can be controlled f...

Page 7: ... installed In this case the only available POWER switch is A there is no switch B The unit is powered on when either of the two POWER switches A or B is turned on With an HK PSU02 unit installed the system continues to function normally as long as either of the two power supply units is operating normally Caution When installing the HK PSU02 in your unit be sure to contact your Sony service repres...

Page 8: ...ut connectors BNC type MKE 8021A Used for SDI interface input and output of video signals between this unit and the switcher or external video devices REMOTE1 GPI CTRL DATA REF IN AC IN A AC IN B U SWITCHER A SWITCHER B REMOTE3 REMOTE2 REMOTE4 GPI 2 REMOTE1 GPI CTRL DATA REF IN AC IN A AC IN B U REMOTE3 REMOTE2 REMOTE4 GPI 2 IN V1 K1 V2 K2 K4 V3 K3 V4 1 2 3 4 OUT V1 K1 V2 K2 K4 V3 K3 V4 MONI OUT 2...

Page 9: ...ontact your Sony service representative For detailed information about setting up the Ethernet switch refer to the documentation supplied with the switch For more information about Ethernet switch connectors see MVS 8000 8000A System Configuration on page 10 h DATA connector RJ 45 Connect to an Ethernet switch The MVS 8000 8000A Multi Format Switcher Processor and the MVS 8000 8000A system s cente...

Page 10: ...eries Reference video signal b Reference video signal b Cross cable Cable with BNC connectors MVS 8400 8300 8200 8000 8000A C Switcher Processor Pack Ethernet switch a VTR DDR Audio Mixer a It is recommended that the CTRL and DATA LAN networks be configured by connecting separate Ethernet switches for each LAN However it is also possible to make connections for both LANs on a single Ethernet switc...

Page 11: ... 8200 8000 8000A C Switcher Processor Pack Cable with BNC connectors AC power supply Video input signal Video output signal Video key signal a For the AC power cord of this unit refer to Accessories not supplied see page 15 in this manual b For the AC power cord of the MVS 8000 8000A refer to Accessories not supplied in the MVS 8400 8300 8200 8000 8000A C Operation Manual c Terminate with the supp...

Page 12: ...R Series HDS X Series Reference video signal b Reference video signal b Cross cable Cable with BNC connectors MVS 8400 8300 8200 8000 8000A C Switcher Processor Pack Ethernet switch a VTR DDR Audio Mixer DCU 2000 C Device Control Unit Pack a It is recommended that the CTRL and DATA LAN networks be configured by connecting separate Ethernet switches for each LAN However it is also possible to make ...

Page 13: ... 240 V AC power supply b AC power supply Reference video signal c 100 to 240 V AC power supply a 100 to 240 V AC power supply b 100 to 240 V AC power supply b Video input signal Video output signal a For the AC power cord of this unit refer to Accessories not supplied see page 15 in this manual b For the AC power cord of the MVS 8000 8000A refer to Accessories not supplied in the MVS 8400 8300 820...

Page 14: ...uring operation and when the unit is powered on Whenever a power error is detected it is reflected immediately by the indicator Meaning of status indicator displays Indicator color Status Description Steps to take Green Lit Operating normally Red LIt Power supply unit fan fault Exchange the fan unit Not lit Power supply unit fault Exchange the power unit ...

Page 15: ...BNC type 75Ω with loop through output HDTV systems HD tri level sync SDTV analog black burst SDTV analog sync SDTV systems Analog black burst analog sync Control connectors CTRL RJ 45 Complies with 100 Base TX standard DATA RJ 45 Complies with 100 Base TX standard REMOTE 1 to 4 D sub 9 pin female Complies with RS 422A standard Data transfer rate 38 4 Kbps GPI GPI2 D sub 25 pin female TTL inputs 8 ...

Page 16: ...Accessories not supplied Operation and Installation Guide 1 supplied only when product is purchased separately MKE 8040A Effects Board Power requirements 12 V DC Power consumption Approx 5 A Dimensions w d 317 380 mm 12 1 2 15 inches Mass Approx 2 kg 4 lb 6 oz Accessories supplied Operation and Installation Guide 1 supplied only when product is purchased separately HK PSU02 Power Supply Unit Power...

Page 17: ... for use by the purchasers of the equipment described in this manual Sony Corporation expressly prohibits the duplication of any portion of this manual or the use thereof for any purpose other than the operation or maintenance of the equipment described in this manual without the express written permission of Sony Corporation ...

Page 18: ...Sony Corporation B P Company Printed in Japan 2004 07 13 2004 MVE 8000A SY 3 855 821 02 1 Printed on 100 recycled paper http www sony net ...

Reviews: