1-21
MVS-8000X/7000X
D2201 to D2204 (E-8) : NEP1 STAT
Internal status indication of external communication IC
(NEP1).
Blinks in order D2201 to D2203 when start up normally,
and D2204 is turned off.
D2301 to D2304 (H-8) : NEP2 STAT
Internal status indication of external communication IC
(NEP2).
Blinks in order D2301 to D2303 when start up normally,
and D2304 is turned off.
D2401 to D2406 (E-1, F-1) : EXT1
Communication status indication of NEP1. Each LED
works as below.
.
D2401 (10) : Lights when linked by 10base-T.
.
D2402 (100) : Lights when linked by 100base-TX.
.
D2403 (1000) : Lights when linked by 1000base-T.
.
D2404 (DUP) : Lights when communicated by full-
duplex.
.
D2405 (RX) : Blinks when receiving the data.
.
D2406 (TX) : Blinks when transmitting the data.
D2501 to D2506 (E-1, F-1) : EXT2
Communication status indication of NEP2. Each LED
works as above.
D2707 to D2709, D2803, D2907 to D2909, D3003
(A-2, B-2) : LINK/ACT P0 to P7
Ethernet communication status indication for internal
communications.
Lights when linked, and blinks when communicating.
D2704 to D2706, D2801, D2904 to D2906, D3001
(A-2, B-2) : 100 P0 to P7
Ethernet communication status indication for internal
communications.
Lights when linked by 100base-TX.
D2701 to D2703, D2802, D2901 to D2903, D3002
(A-2, B-2) : 1000 P0 to P7
Ethernet communication status indication for internal
communications.
Lights when 1000base-T link is established.
P0 to P7 indicate ports connected with other boards and are
assigned as shown below.
.
P0 : SLOT10
.
P1 : SLOT16
.
P2 : SLOT8
.
P3 : SLOT1
.
P4 : SLOT7
.
P5 : SLOT4
.
P6 : SLOT2
.
P7 : reserved
D3601 to D3604 (N-11) : IC5 STAT
IC5 status indication.
Indicates the internal status. (For maintenance)
D3605 (B-1) : POWER
Power supply status indication.
Lights in green when all power supply on the board are
normally. If the power supply has abnormality, turns off.
D3606 (B-1) : BECON
For future expansion.
D3607 (B-1) ; STATUS
For future expansion.
D3701 (L-1) : CF LED0
CF card controller status indication.
Lights or blinks when communicate with CF card.
D3702 (M-1) : CF LED2
CF card controller status indication. (Not used)
D3703 (M-1) : CF LED1
CF card controller status indication. (Not used)
D3704 (M-1) : CF DET
Lights when CF card is inserted.