1-25
MVS-8000X/7000X
D306 (B-1) : 2.5 V-1
+
2.5 V-1 power supply status indication.
Lights when the
+
2.5 V power is supplied.
D308 (A-1) : 1.8 V
+
1.8 V power supply status indication.
Lights when the
+
1.8 V power is supplied.
D310 (A-1) : 5 V
+
5 V power supply status indication.
Lights when the
+
5 V power is supplied.
D307 (B-1) : 1.2 V-2
+
1.2 V-2 power supply status indication.
Lights when the
+
1.2 V power is supplied.
D401 (F-1) : CA RESET B
The board reset status indication. Lights when the follow-
ing occurs.
.
When S401/S402 is pressed.
.
When power is not properly supplied.
.
When a reset request is made from software.
.
When IC1/IC5 does not start up properly.
D402 (F-1) : CA RESET A
The board reset status indication. Lights when the follow-
ing occurs.
.
When S401/S402 is pressed.
.
When
+
12 V,
+
3.3 V, or
+
1.2 V-1 power is not properly
supplied.
.
When a reset request is made from software.
.
When IC1/IC5 does not start up properly
D403 (F-1) : SWER RESET
System reset status indication. Lights when the following
occurs.
.
When S402 is pressed.
.
When
+
12 V,
+
3.3 V, or
+
1.2 V-1 power is not properly
supplied.
.
When a reset request is made from software.
.
When IC1/IC5 does not start up properly
D801 (F-6) : IC1 ERR
Error status indication of IC1. Lights when the con
fi
gura-
tion error is occurred.
D802 to D804 (E-4, F-4) : IC1 STAT
IC1 error status indication.
Indicates the internal status. (For maintenance)
D917 to D920 (P-1), ND901 (N-1), ND902 (P-1) :
CPU STATUS
CPU software status indication.
D1101 (E-1) : REF EXT
REF IN status indication.
Lights when REF signal is not input to the REF IN termi-
nal. Turn off when identi
fi
ed the REF signal.
D1102 (E-1) : PLL LOCK
REF IN status indication.
Lights when the REF IN signal matches with the switcher
format setup.
D2707 to D2709, D2803, D2907 to D2909, D3003
(A-2, B-2) : LINK/ACT P0 to P7
Ethernet communication status indication for internal
communications.
Lights when linked, and blinks when communicating.
D2704 to D2706, D2801, D2904 to D2906, D3001
(A-2, B-2) : 100 P0 to P7
Ethernet communication status indication for internal
communications.
Lights when linked by 100base-TX.
D2701 to D2703, D2802, D2901 to D2903, D3002
(A-2, B-2) : 1000 P0 to P7
Ethernet communication status indication for internal
communications.
Lights when 1000base-T link is established.
P0 to P7 indicate ports connected with other boards and are
assigned as shown below.
.
P0 : SLOT10
.
P1 : SLOT16
.
P2 : SLOT8
.
P3 : SLOT1
.
P4 : SLOT7
.
P5 : SLOT4
.
P6 : SLOT2
.
P7 : reserved
D3601 to D3604 (N-11) : IC5 STAT
IC5 status indication.
Indicates the internal status. (For maintenance)