1-46
MVS-8000X/7000X
1-9. System Connection
Con
fi
gure the MVS-8000X series system connections referring to the connection example as shown below.
1. Connection example of the MVS-8000X system
n
The following connection can also be made for the MVS-7000X system.
Ethernet switch
b)
Ethernet switch
b)
Reference video
signal
c)
c)
c)
IXS Series
BKS-R Series
Reference video signal
MKS-8010B System
Control Unit
BVE-9100 Editing Control
System
MVS-8000X Multi Format Switcher
Processor
a)
MKS-8700 Device Control
Unit Pack
The illustration represents the MVS-8000X.
b)
a)
It is recommended that the CTRL and DATA LAN networks be
configured by connecting separate Ethernet switches for each
LAN.
c) Terminate with the supplied 75
Ω
terminators.
d) This figure shows the rear panel when one MKE-8021A is
installed in the MVE-8000A.
e) The following cannot be used for connection to the MVS-8000X/
MVS-7000X.
Model
Relevant serial numbers
MKS-8010
All
MKS-8010A
10001 to 11196
MKS-9011A
10001 to 12000
MKS-9012A
10001 to 21000
DDR
Audio Mixer
VTR
Reference video
signal
c)
Reference video
signal
MVE-8000A-C DME
Processor Pack
d)
Cross cable
Cable with BNC-type
connectors
REMOTE 1
DATA
DATA
CTRL
CTRL
PERIPH
NETWORK B (DATA)
NETWORK B (CTRL)
e)