1-1
MVS-8000X/7000X
1-1. Operating
Environment
Operating guaranteed temperature :
+
5
d
C to
+
40
d
C
Performance guaranteed temperature :
+
10
d
C to
+
35
d
C
Operating humidity :
10 % to 90 %
(relative
humidity)
Storage temperature :
_
20
d
C to
+
60
d
C
Mass (when all options are installed) :
MVS-8000X :
Approx. 58 kg
MVS-7000X :
Approx. 49 kg
Prohibited locations for installation
.
Areas where the unit will be exposed do direct sunlight
or any other strong lights.
.
Dusty areas
.
Areas subject to vibration.
.
Areas with strong electric or magnetic
fi
elds.
.
Areas near heat sources.
.
Areas subject to electrical noise.
.
Areas subject where is subjected to static electricity.
Ventilation
The inside of the MVS-8000X/MVS-7000X is cooled by a
fan (right side).
The power supply can be damaged if the exhaust vent (right
side) and air intake (front panel) are blocked or the fan is
stopped.
Therefore, leave a blank space of more than 10 cm in the
front and both sides of the MVS-8000X.
Section 1
Installation
1-2. Power
Supply
1-2-1. Power Speci
fi
cations
A switching regulator is used for the power supply of this
unit. The voltage within the range of 100 V to 240 V can be
used without changing the supply voltage.
Power requirements :
AC 100 to 240 V
?
10 %
Power frequency :
50/60 Hz
Current consumption (when all options are installed) :
MVS-8000X : 15 to 6.5 A
MVS-7000X : 15 to 6.5 A
m
.
As the inrush current at turn-on is a maximum 100 A (at
100 V)/175 A (at 230 V), the capacity of the AC power
source must be commensurate with this load.
If the capacity of the AC power is not adequately large,
the AC power source braker will operate or the unit will
abnormally operate.
.
The MVS-8000X contains the three power supply units
as the standard con
fi
guration. A maximum of four power
supply units may be installed. When starting up the
MVS-8000X, be sure to turn on the power of three or
more power supply units.
.
The MVS-7000X contains the two power supply units as
the standard con
fi
guration. A maximum of four power
supply units may be installed. When starting up the
MVS-7000X, be sure to turn on the power of two or
more power supply units.
Summary of Contents for MVS-8000X System
Page 4: ......
Page 54: ......
Page 58: ...Sony Corporation MVS 7000X SY MVS 8000X SY E 4 189 509 03 Printed in Japan 2011 5 08 2010 ...