– 10 –
SECTION 5
ELECTRICAL ADJUSTMENTS
Notes for Adjustment
• In this set, automatic adjustment of CD and MO can be per-
formed by entering the test mode. (See page 6)
• Adjustments are performed in the overall adjustment mode. If
an item is determined as NG, the item is readjusted in servo
mode.
Adjustment Method in Overall Adjustment Mode
1. Enter the test mode and press the VOL + key to enter overall
adjustment mode.
2. Insert the CD test disc TDYS-1 (Parts No. 4-963-646-01) or
SONY MO disc (recorded) commercially available.
3. Press the
”
/
+
key. The disc is determined whether it is CD
or MO and each adjustment mode is set. Automatic adjust-
ments are performed in the order of the items listed below.
• In CD Automatic adjustment Mode
No.
Mode
Description
1
061
Sled in
2
062
Sled out
3
071
Focus search
4
051
CD EF balance
5
053
CD ABCD gain
6
051
CD EF balance
7
052
CD tracking offset
8
054
CD focus gain
9
055
CD tracking gain
10
056
CD focus bias
• In MO Automatic adjustment Mode
No.
Mode
Description
1
061
Sled in
2
062
Sled out
3
071
Focus search
4
031
MO EF balance
5
033
MO ABCD gain
6
031
MO EF balance
7
032
MO tracking offset
8
034
MO focus gain
9
035
MO tracking gain
10
036
MO focus bias
* Remote commander display during automatic adjustment
4. If result of automatic adjustment is OK, the following display
appears.
5. If result of automatic adjustment is NG, the following display
appears.
* If NG, enter servo mode to perform automatic adjustment of the
item determined as NG.
Adjustment in Servo Mode Method
1. When each adjustment mode is set according to the structure
of servo mode, the lower two digits of the mode No. and the
adjustment value written in EEPROM are displayed and lit on
the LCD on the remote commander. (See page 6)
2. When the
P
key is pressed, the following display appears and
the automatic adjustment is performed.
Note:
Although the VOL +/– keys can be used to change the adjust-
ment value to any value, they should not be used whenever
possible.
3. When the automatic adjustment is completed, the flashing ad-
justment value is lit.
055
Adjustment value (flashing)
Mode No. under adjustment
056
End-OK
052
NG
Error code
NG mode No.
052
Adjustment value (lit)
Mode No.
052
Adjustment value (flashing)
052
Adjustment value (lit)
Summary of Contents for MZ-E80