16
MZ-R701/R701DPC
4-11. Key Check Mode
This set can check if the set and remote commander function nor-
mally.
• Setting method of key check mode
1. Setting the test mode (see page 12).
2. Press the
[T MARK]
key for several seconds (about 3 seconds)
activates the key check mode. (At the last two digits, AD value
of remote commander key line is displayed in hexadecimal)
3. When each key on the set and on remote commander is pressed,
its name is displayed on the LCD. (The operated position is
displayed for 4 seconds after the slide switch is operated. If
any other key is pressed during this display, the remote com-
mander LCD switches to its name display)
Example1: When
>
key on the set is pressed:
Example2: When
N
>
key on the remote commander is
pressed:
4-10. Sound Skip Check Result Display Mode
This set can display the count of errors that occurred during the
recording/playing for checking.
• Setting method of sound skip check result display
mode
1. Set the test mode (see page 12).
2. Press the
N
key or
[REC]
key, and the playing or recording
sound skip result display mode becomes active respectively
where the LCD displays the following.
3. When the
N
key is pressed, total error count is displayed on
the LCD, and each time the
>
key is pressed, the display
item moves down by one as shown below. Also, if the
.
key
is pressed, the display item moves up by one, then if the
[REC]
key is pressed, the display in the record mode appears.
When the
[REC]
key is pressed, total error count is displayed
on the LCD, and each time the
>
key is pressed, the display
item moves down by one as shown below. Also, if the
.
key
is pressed, the display item moves up by one, then if
the
N
key is pressed, the display in the play mode appears.
This set LCD display
Total count record
system errors (hex.)
0 00
P R
Total count of play
system errors (hex.)
• Cause of sound skip error
Cause of error
Description of error
EIB
Sound error correction error
Play
Stat
Decoder status error
Adrs
Address access error
BEmp
Buffer is empty
BOvr
Buffer is full, and sounds were
dumped
Record
Bful
Buffer capacity becomes less,
and forcible writing occurred
Rtry
Retry times over
4. To quit the sound skip check result display mode and to return
to the test mode (display check mode), press the
x
key.
0 00
P R
P R
0 00
EIB
0 00
Stat
0 00
Adre
0 00
BEmp
0 00
######
######
0 00
P R
0 00
BOvr
0 00
Bful
0 00
Rtry
0 00
######
Playing sound skip
result display
Recording sound skip
result display
: Total play/record errors (hex.)
: Counter of sound skip check each item (hex.)
: 6-digit address where sound was skipped last (hex.)
This set LCD display
0 00
: AD value of the remote commander key
(hexadecimal OO to FF)
This set LCD display
0 00
FF
: AD value of the remote commander key
(hexadecimal OO to FF)
This set LCD display
0 00
rPLAY
: AD value of the remote commander key
(hexadecimal OO to FF)