11
NW-E403/E405/E407
SECTION 3
TEST MODE
STANDING PROCEDURE
Procedure 1: In HOLD state, while pushing
Nx
button, push
[REST]
.
When the test mode is set, the LCD display appears
as shown below.
Procedure 2: After starting up test mode, the following contents
can be checked.
TEST MODE
•
Nx
button
The KEY test mode is activated. All key inputs are completed,
then
Nx
button is pressed, restart. (Be aware that the
initialization is included on all key input.)
•
[MENU]
button
“MENU KEY” appear.
•
[DISP]
button
“DISP KEY” appear.
• +
>
knob
Change charge mode (100 mA/500 mA).
•
.
– knob
Charge on/off.
•
[GROUP]
on state
LCD checked pattern.
•
[GROUP]
off state
“GROUP KEY OFF” appears.
•
[GROUP ]
knob
All LCD lights on.
•
[GROUP ]
knob
All LCD lights off.
•
[VOL +]
button
BEEP turns on.
•
[VOL --]
button
BEEP turns off.
•
[ REPEAT SOUND]
button
Initialized. (Turns to the factory preset state, time, volume setting
and so on.)
The music data, files and so on in the memory are not changed.
•
256M 1.00.04 G10
<
,