4
NW-E002F/E003F/E005F
Fig-1
Fig-3
Fig-4
Fig-2
NOTES ON ARRANGE THE BATTERY WIRES AND SW PWB WIRES
HP GUIDE
HP GUIDE
BATTERY WIRES
BATTERY WIRES
BATTERY WIRES
SW PWB WIRES
SW PWB WIRES
RIB
BATTERY WIRES
1. Arrange BATTERY WIRES as in Fig-1 and Fig-2.
2. Arrange SW PWB WIRES to arrow direction (Fig-3) and attach the HP GUIDE.
3. Arrange BATTERY WIRES and SW PWB WIRES under the RIB as Fig-4 then attach the battery.
NOTES ON REPLACEMENT OF Ref. No. 15 (CABINET (MID) ASSY)
Ref. No. 15 has both the suffix-1 and the suffix-2 on part number.
Please confirm by the following two methods at replacement.
1. Whether it has Ref. No. 30 (HP GUIDE SHEET) or not.
•
The one with Ref. No. 30
t
Using the suffix-2 of Ref. No. 15.
•
The one not with Ref. No. 30
t
Using the suffix-1 of Ref. No.15.
2. Distinguish by the following serial number.
Suffix-2 is adopted since the following serial number.
NW-E002F : from 5076285
NW-E003F : from 5070762
t
Using the suffix-2 of Ref. No. 15.
NW-E005F : from 5022246
Ver. 1.3
CAUTION
Danger of explosion if battery is incorrectly replaced.
Replace only with the same or equivalent type.